308487
5
Installation
PRESSURIZED EQUIPMENT HAZARD
The equipment stays pressurized until pressure is
manually relieved. To reduce the risk of serious
injury from pressurized fluid, accidental spray from
the dispense valve, or splashing fluid, follow the
Pressure Relief Procedure
when you
D
Are instructed to relieve pressure
D
Check, clean, or service any system equipment
D
Install or clean fluid nozzles or filter
WARNING
Pressure Relief Procedure
1.
Turn off the power supply to the pump.
2.
Trigger the dispense valve into a waste container
to relieve pressure.
3.
Open any bleed-type master air valves and fluid
drain valves in the system.
4.
Leave the drain valve open until you are ready to
pressurize the system.
Pre-Installation Procedure
1.
Install the battery. See
Replacing the Battery
on
page 18.
2.
Relieve the pressure.
WARNING
To reduce the risk of serious injury whenever you
are instructed to relieve pressure, always follow the
Pressure Relief Procedure
above.
3.
Close the shut-off valve (item J in Fig. 1).
4.
Ground the hose and reel or console. See
Grounding
on page 7.
NOTE:
Do not use PTFE tape on the pipe joints; it
may cause a loss of ground across the pipe joint.
Installation Procedure
If this is a new installation, or if the fluid in the
lines is contaminated, flush the lines before you
install the metered valve. Contaminated lines
could cause the valve to leak.
CAUTION
1.
If this is an existing installation, go to step 7.
Steps 3 through 6 are the
Flushing Procedure
.
2.
Make sure the main fluid outlet valve at the pump
is closed, the air pressure to the pump motor is
adjusted, and the air valve is open. Slowly open
main fluid valve.
3.
Close the fluid shut-off valve (J) at each dispense
position.
4.
Place the hose end (with no dispense valve con-
nected) into a container for waste oil. Secure the
hose in the container so it will not come out during
flushing. If you have multiple dispense positions,
first flush the dispense position farthest from the
pump, and work your way toward the pump.
5.
Slowly open the shut-off valve (J) at the dispense
position. Flush out a sufficient amount of oil to
ensure that the entire system is clean, and close
the valve.
6.
Repeat step 5 at all other dispense positions.
7.
Relieve the pressure.
WARNING
To reduce the risk of serious injury, whenever you
are instructed to relieve pressure, always follow the
Pressure Relief Procedure
at left.
8.
Slide the swivel cover (4) of the EM5 onto the
hose, small end first. See Fig. 3.
9.
Apply thread sealant to the the male threads of the
hose fitting, thread the hose fitting into the swivel
(3) of the EM5, and tighten firmly. See Fig. 3.
NOTE:
Make sure you let the sealant cure to the
manufacturer’s recommendations before you let
fluid into the system.
3
hose fitting
Slide onto
hose before
connecting.
06187