14
308487
Operation
Checking Segments in the Display
When you press the Reset button when the display is
awake, the Segment Check is displayed briefly. This
display allows you to check for burned out segments in
the display. Press the Reset button repeatedly to get a
good look at each segment in the display. The Seg-
ment Check should show all of the segments shown
below.
06044
LITERS
PTS QTS
GAL
R-TOTAL
AUTO
CAL
,
,
,
Maximum Working Pressure: 70 bar (1000 PSI)
Min. Dispense Volume
0.5 liter
(0.13 gal)
Minimum Flow Rate
1.0 l/min.
(0.26 gpm)
Maximum Flow Rate
15.0 l/min.
(3.26 gpm)
Dispensing Fluid in Standard Mode
NOTE:
All buttons are disabled while fluid is being
dispensed.
1.
Press the Reset button.
0.000
is shown on the display.
2.
Squeeze the trigger.
Fluid begins to flow, and the amount shown on the
display counts up from zero.
3.
Release the trigger when you have dispensed the
desired amount of fluid.
Fluid flow stops, and the amount you have dispensed
is shown on the display.
NOTE:
When you release the trigger, the nozzle
should prevent fluid from running out of the exten-
sion. If fluid does run out, see
Replacing the
Nozzle
on page 19.
Dispensing Fluid in Auto Alarm Mode
NOTE:
All buttons are disabled while fluid is being
dispensed.
1.
Press the Auto button.
The stored predetermined dispense amount is shown
on the display if an amount is stored.
2.
If you do not want to change the predetermined
dispense amount shown on the display, skip this
step. If you want to change the amount, do the
following:
Press the 10 button to change the 10s digit, press the
1.0 button to change the 1s digit, and press the 0.1
button the change the first decimal digit.
3.
Squeeze the trigger.
Fluid begins to flow, and the amount shown on the
display counts down from the predetermined amount if
the unit is in UPOFF mode. The amount counts up
from zero if the unit is in UP ON mode. See
UP On /
UPOFF Selection Procedure
on page 13.
The unit makes three short audible beeps shortly
before it dispenses the predetermined amount. Then it
makes one long audible beep when the predetermined
amount of fluid is dispensed.
NOTE:
The three short beeps occur within a certain
volume of the predetermined amount, as follows:
QTS or LITERS: Unit beeps within 0.4 quarts or liters
of predetermined amount.
PTS: Unit beeps within 0.5 pints of predetermined
amount.
GAL: Unit beeps within 0.1 gallons of predetermined
amount.
To stop dispensing, you must release the trigger.
Fluid flow does not stop automatically.
4.
Release the trigger.
The amount dispensed is shown on the display.
5.
If you want to resume dispensing
toward
the
predetermined dispense amount, squeeze the
trigger again. If you want to dispense
from zero
,
press the Reset button.