Installation
332514J
9
4. Verify gasket (c) is in place on top the reservoir
cover, laying flat and that the holes (e) in the gasket
align with the holes in the cover (F
IG
. 7).
5. Install pump down-tube through opening in the cen-
ter of the gasket and tank / reservoir cover and into
tank / reservoir.
6. Align holes in pump base with holes in tank / reser-
voir cover (F
IG
. 8). Securely fasten pump to tank /
reservoir cover using screws (a) and washers (b)
removed in Step 1, page 8.
NOTE:
When the pump is correctly installed on the
Graco tank, the breather (J) will be below the control
box (115) as shown in F
IG
. 9.
7. Reinstall cover (126) using bolts (128). Use a
wrench to tighten bolts securely (F
IG
. 10).
F
IG
. 6
F
IG
. 7
HEAVY EQUIPMENT HAZARD
Lifting or moving heavy equipment incorrectly can
cause serious injury. To avoid serious injuries, such as
muscle strain or back injuries, when moving pump
always use a lifting aid secured to the pump lift ring .
See Technical Data, included in the pump instruction
manual for pump weight information.
208
d
c
e
e
e
F
IG
. 8
F
IG
. 9
NOTICE
To prevent damage to the unit:
• Check breather (J) vent for proper operation
before filling reservoir.
• Open overflow port (H) before filling reservoir to
visually inspect lubrication level.
• Do not fill reservoir beyond overflow port (H).
• Do not use breather vent as a port to fill
reservoir.
a
b
J
115
133
Summary of Contents for Dyna-Star 77X000