Repair
332514J
33
Reassembly
NOTE:
•
Use all new parts included in kit for reassembly.
1. Install new motor control board (117) in housing
(115) using screws (118) (F
IG
. 67). Torque to 8 - 10
in. lbs (0.9 - 1.1 N.m).
2. Connect source to power input (A and B) and pump
signal connections (C and D) (F
IG
. 65 and A,B,C,D,
page 13). Torque to 5.5 - 7 in. lbs (0.62 - 0.79 N.m).
3. Match green, yellow and blue wires of motor to ter-
minals of same color (written on the control board).
Secure wires to terminals using washers (135) and
nuts (134) (F
IG
. 59). Torque to 8 - 10 in. lbs (0.9 -
1.1 N.m).
4. Connect sensor cable (117a) (F
IG
. 69).
F
IG
. 67
F
IG
. 68
118
117
115
A
B
C
D
F
IG
. 69
134
117a
115
134
135
Summary of Contents for Dyna-Star 77X000