Repair
28
332514J
NOTE:
When the pump is correctly installed, the
breather (J) will be below the control box (115) as
shown in F
IG
. 49.
27. Reinstall cover (126) using bolts (128). Use a
wrench to tighten bolts securely (F
IG
. 50).
28. Connect the timer/controller (F) (user supplied, if
used).
29. Connect High Pressure Lubricant Supply Line (D) to
the Lubricant Output Connection (0) (F
IG
. 51) on the
Vent Valve or Manifold.
30. Connect power to pump.
31. See Operation instructions for pump priming and
reservoir filling instructions, page 15.
Motor Replacement: Kit 24T862
•
Reference numbers used in the following instruc-
tions refer to Parts pages beginning on page 35.
•
Upper case letters used in the following instructions
refer to Typical Installation provided on page 6 or 7.
•
Lower case letters used in the following instructions
refer to component parts or user provided parts.
•
Unless otherwise noted, keep all parts for reassem-
bly. Inspect and clean parts as needed prior to using
them for reassembly.
•
Use all new parts included in kit for reassembly.
Disassembly
1. Disconnect Dyna-Star pump from main power
source.
2.
Relieve pressure
(see Pressure Relief procedure,
page 8).
3. Disconnect Timer/Controller (F) (user supplied, if
used).
4. Disconnect High Pressure Lubricant Supply Line (D)
to the Lubricant Output Connection (0) (F
IG
. 52) on
the Vent Valve or Manifold.
F
IG
. 49
F
IG
. 50
F
IG
. 51: Lubricant Outlet Connection
J
115
126
128
0
D
F
IG
. 52: Lubricant Outlet Connection
0
D
Summary of Contents for Dyna-Star 77X000