13
309077
Installation
Connecting the Electrical Control Panel to
a Power Source
The electrical control panel (Fig. 4) comes already
attached and wired to the ram, however before the
supply unit becomes functional, you must connect the
electrical control panel to a power source.
WARNING
ELECTRIC SHOCK HAZARD
Do not connect the electrical control
panel to a power source unless you are
a trained professional. Failure to follow
standard procedures or to observe the necessary
precautions could result in serious bodily injury or
equipment damage.
Fig. 4
480 VOLTS
Have a trained electrician connect the electrical control
panel (Fig. 4) to a grounded electrical source that has
the required service ratings:
CAUTION
If power and grounding connections are not done
properly, the equipment will be damaged and the
warranty will be voided.
Control
Panel
Part No.
VAC
Hz
Phase
Full
Load
Amps
C32429
480
60
3
34.6
For information about specific terminal locations and
connections, see
Schematics
on page 64 for wiring
diagram information.
To connect the control panel to the electrical source:
1. Create an opening in the control panel‘s housing
for the conduit that will enclose the wire from the
facility’s power source.
2. Thread the wire from the power source into the
control panel housing, and then connect the power
source wires to the appropriate terminals on the
DISCONNECT switch.
Summary of Contents for 309077
Page 9: ...9 309077 Typical Installation 4 Regulator Air Control Module Fig 2 O C D I A E B 9402A ...
Page 47: ...47 309077 Notes ...
Page 64: ...64 309077 Schematics 122 122 ...
Page 65: ...65 309077 Schematics 121 121 TEMPERATURE CONTROL TEMPERATURE CONTROL ...
Page 66: ...66 309077 Schematics 170 170 TEMPERATURE CONTROL TEMPERATURE CONTROL TEMPERATURE CONTROL ...
Page 68: ...68 309077 Schematics ...
Page 69: ...69 309077 Notes ...