31
309077
Operation
Emergency Stop
1. On the electrical control panel (Fig. 25):
a. Turn the CONTROL ON ()U switch to OFF.
b. Turn OFF the main electrical disconnect (AA).
Fig. 25
U
AA
480 VOLTS
2. Stop the pump by closing the bleed-type master air
valve (C), as shown in Fig. 26.
3. To stop the ram from moving (Fig. 26):
a. Close the master air lock-out valve (B).
b. Move the hand valve (110) to the OFF posi-
tion. This valve shuts off the air supply to the
ram.
Fig. 26
B
C
110