Appendix B
309738L
89
Setup Screen 2: Calibrate Screen (Bead Control Mode)
Notes:
The values for the pressure loop constants Kp and Ki can also be directly entered by the user in the OTHER setup
screen.
100% Command Flow
cc/min
In Manual Mode, press
to begin calibration
Calibration required (valid)
Press
to see details
Output
345 psi
2134 cc/min
Desired Output
333 psi
2115 cc/min
Kp 105
Ki
4
346 psi
Max System Output
3405 cc/min
622 psi
Volume Compensation -2%
112%
Dispense
Calibrate
Other
No Active Faults
09/06/02 10:00
2548
Description
Possible Values
Default Value
Hour
0-23
N/A
Minute
0-59
N/A
Day
1-31
N/A
Month
1-12
N/A
Year
2000-2099
N/A
Date Format
mm/dd/yy-dd/mm/yy
mm/dd/yy
100% commanded flow rate
50-150%
100%
Pressure tuning status
In process, complete
N/A
Flow calibration status
In process, complete
N/A
Flow calibration result
Required, Valid
Required
Pressure
0-9999
N/A
Pressure units
psi or bar
psi
Actual flow rate
0-9999cc/min
N/A
Desired outlet pressure
0-9999
N/A
Desired flow rate
0-9999
N/A
Calculated optimal KP
note 1
0 to 9999
100
Calculated optimal Ki
note 1
0 to 9999
6
Pressure for 100% flow
0 to 9999
N/A
System maximum flow with completely open
reg
0 to 9999
N/A
Compensation zero offset
-50 to 399%
0%
Compensation peak
25 to 400
100%
Active Fault
Numerous text strings
N/A