Run Screen (Volume Control Mode)
The purpose of this screen is to display the required run parameters.
Notes:
1.
Reverse image indicates Run Mode Bead Scale is enabled in the setup
other screen.
2.
Target Volume should change based on style.
3.
Error Values reflect the completed last job's data
.
Description
Possible Values
Default Value
Hour
0-23
N/A
Minute
0-59
N/A
Day
1-31
N/A
Month
1-12
N/A
Year
2000-2099
N/A
Date Format
mm/dd/yy-dd/mm/yy
mm/dd/yy
Pressure
0-9999
N/A
Pressure Units
psi or bar
psi
Actual Flow Rate
0-9999 cc/min
N/A
Command
0-100%
N/A
Bead Scale
note 1
50-150%
100%
Dispense Mode
Auto or Manual
N/A
Control Mode
Bead Control, Volume Monitor,
Batch Dispense, or Pressure
Control
Bead Control
Style
1 to 4
1
Target Volume
note 2
0 to 9999.9 cc
25.0 cc
Actual Volume
0 to 9,999,999.9 cc
N/A
Volume Error
note 3
-100.0 to 999.9%
N/A
Active Fault
Numerous text strings
N/A
Output:
345 psi
213 cc/min
Command: 100%
% Bead Scale
Mode:
Auto
Volume Monitor
VOLUME:
Target:
414 cc
Measured:
- 0.5%
No Active Faults
02/25/03 10:00
112