PrecisionFlo LT User Interface
309738L
29
Automation Modes
The PrecisionFlo LT system has two automation com-
mand modes:
•
Fixed mode –
enables the PrecisionFlo LT system to
dispense at preset rate in the control unit.
•
Analog mode –
enables the PrecisionFlo LT system
to dispense at a rate proportional to a 0-10 VDC ana-
log input signal from the automation unit.
Refer to
for more information on Automation Command Modes.
Setting Automation Mode
On the keypad, perform the following steps:
1.
With the system in setup mode (key switch clock
wise), press the right arrow key
until the
OTHER screen appears. The command mode is
indicated on this screen, either Fixed or Analog.
2.
To change the mode, press the down arrow key
until the cursor is over the desired mode cell.
3.
Press Enter and use the up and down arrow keys,
or
to change values.
4.
Press Enter.