5 MODULATOR 2:
A 5-step shapable modulator. Step 1: delay time, step 2: rise time to full value, step 3:
hold time at full value, step 4: fall time to zero, step 5: hold time at zero value. Can
be key-triggered, looped or key-triggered and looped. It has 2 sets of settings, that can
be morphed between, using any modulator.
6 LFO 1
7 LFO 2
The LFO's waveforms are continuously variable from triangle to saw to square to
pulse. The LFO's can be both wave and rate-modulated, using any modulator. Both
LFO's can also be key-synced, and LFO wave start-point can be adjusted.
8 Random Voltage
Each time it is triggered, it outputs a new random value. Trigger sources are: LFO1,
LFO2 or key.
9 Random Pulse
A squared version of the random voltage with adjustable pw. When the random
voltage puts out a value above the pw, the output of this will be zero. When the
random voltage puts out a value below the pw, the output of this will be max.
T1
T2
T3
T4
T5