background image

2

REPLACEMENT PARTS

o

RdERInG

 P

aRtS

When reporting shortages or damages, or ordering repair 

parts, give the complete unit model and serial numbers as 

stamped on the unit’s nameplate. 

Replacement parts for this appliance are available through 

your contractor or local distributor. Your nearest distributor 

can be located online at https://partner.goodmanmfg.com 

or by contacting: 

CONSUMER AFFAIRS

GOODMAN MANUFACTURING COMPANY, L.P.

7401 SECURITY WAY

HOUSTON, TEXAS 77040

(713) 254-4729

SAFETY INSTRUCTIONS

   REcoGnIZE tHIS SyMbol aS a SafEty    

 

PREcaUtIon. 

These installation instructions cover the outdoor 

installation of single package heating and cooling units.  

See the Specification Sheet applicable to your model for 

information regarding accessories.

*notE:  P

lEaSE

 

contact

 

yoUR

 

dIStRIbUtoR

 

oR

 

oUR

 

WEbSItE

 

foR

 

tHE

 

aPPlIcablE

 S

PEcIfIcatIon

 S

HEEt

 

REfERREd

 

to

 

In

 

tHIS

 

ManUal

.

t

o

 t

HE

 I

nStallER

Before installing this unit, please read this manual to 

familiarize  yourself on the specific items which must be 

adhered to, including maximum external static pressure to 

unit, air temperature rise, minimum or maximum CFM and 

motor speed connections. 

Keep this literature in a safe place for future reference.

WARNING

I

f

 

tHE

 

InfoRMatIon

 

In

 

tHESE

 

InStRUctIonS

 

IS

 

not

 

folloWEd

 

Exactly

a

 

fIRE

 

oR

 

ExPloSIon

 

May

 

RESUlt

 

caUSInG

 

PRoPERty

 

daMaGE

PERSonal

 

InjURy

 

oR

 

loSS

 

of

 

lIfE

do

 

not

 

StoRE

 

oR

 

USE

 

GaSolInE

 

oR

 

otHER

 

flaMMablE

 

vaPoRS

 

and

 

lIqUIdS

 

In

 

tHE

 

vIcInIty

 

of

 

tHIS

 

oR

 

any

 

otHER

 

aPPlIancE

- WHat to do If yoU SMEll GaS: 

• d

o

 

not

 

tRy

 

to

 

lIGHt

 

any

 

aPPlIancE

.

• d

o

 

not

 

toUcH

 

any

 

ElEctRIcal

 

SWItcH

do

 

not

 

USE

 

any

 

PHonE

 

In

 

yoUR

 

bUIldInG

• I

MMEdIatEly

 

call

 

yoUR

 

GaS

 

SUPPlIER

 

fRoM

 

a

 

nEIGHboR

S

 

PHonE

. f

olloW

 

tHE

 

GaS

 

SUPPlIER

S

 

InStRUctIonS

. I

f

 

yoU

 

cannot

 

REacH

 

yoUR

 

GaS

 

SUPPlIER

call

 

tHE

 

fIRE

 

dEPaRtMEnt

- I

nStallatIon

 

and

 

SERvIcE

 

MUSt

 

bE

 

PERfoRMEd

 

by

 

a

 

qUalIfIEd

 

InStallER

SERvIcE

 

aGEncy

 

oR

 

tHE

 

GaS

 

SUPPlIER

WARNING

t

o

 

PREvEnt

 

tHE

 

RISk

 

of

 

PRoPERty

 

daMaGE

PERSonal

 

InjURy

oR

 

dEatH

do

 

not

 

StoRE

 

coMbUStIblE

 

MatERIalS

 

oR

 

USE

 

GaSolInE

 

oR

 

otHER

 

flaMMablE

 

lIqUIdS

 

oR

 

vaPoRS

 

In

 

tHE

 

vIcInIty

 

of

 

tHIS

 

aPPlIancE

WARNING

S

HoUld

 

ovERHEatInG

 

occUR

 

oR

 

tHE

 

GaS

 

SUPPly

 

faIl

 

to

 

SHUt

 

off

tHURn

 

off

 

tHE

 

ManUal

 

GaS

 

SHUtoff

 

valvE

 

ExtERnal

 

to

 

tHE

 

fURnacE

 

bEfoRE

 

tURnInG

 

off

 

tHE

 

ElEctRIcal

 

SUPPly

.

CAUTION

S

HEEt

 

MEtal

 

PaRtS

ScREWS

clIPS

 

and

 

SIMIlaR

 

ItEMS

 

InHEREntly

 

HavE

 

SHaRP

 

EdGES

and

 

It

 

IS

 

nEcESSaRy

 

tHat

 

tHE

 

InStallER

 

and

 

SERvIcE

 

PERSonnEl

 

ExERcISE

 

caUtIon

WARNING

d

o

 

not

 

connEct

 

to

 

oR

 

USE

 

any

 

dEvIcE

 

tHat

 

IS

 

not

 

dESIGn

 

cERtIfIEd

 

by

 

tHE

 

ManUfactURER

 

foR

 

USE

 

WItH

 

tHIS

 

UnIt

. S

ERIoUS

 

PRoPERty

 

daMaGE

PERSonal

 

InjURy

REdUcEd

 

UnIt

 

PERfoRMancE

 

and

/

oR

 

HaZaRdoUS

 

condItIonS

 

May

 

RESUlt

 

fRoM

 

tHE

 

USE

 

of

 

SUcH

 

non

-

aPPRovEd

 

dEvIcES

WARNING

t

o

 

avoId

 

PRoPERty

 

daMaGE

PERSonal

 

InjURy

 

oR

 

dEatH

do

 

not

 

USE

 

tHIS

 

UnIt

 

If

 

any

 

PaRt

 

HaS

 

bEEn

 

UndER

 

WatER

. I

MMEdIatEly

 

call

 

a

 

qUalIfIEd

 

SERvIcE

 

tEcHnIcIan

 

to

 

InSPEct

 

tHE

 

fURnacE

 

and

 

to

 

REPlacE

 

any

 

PaRt

 

of

 

tHE

 

contRol

 

SyStEM

 

and

 

any

 

GaS

 

contRol

 

HavInG

 

bEEn

 

UndER

 

WatER

WARNING

t

HIS

 

UnIt

 

MUSt

 

not

 

bE

 

USEd

 

aS

 

a

 “

conStRUctIon

 

HEatER

” 

dURInG

 

tHE

 

fInISHInG

 

PHaSES

 

of

 

conStRUctIon

 

on

 

a

 

nEW

 

StRUctURE

. t

HIS

 

tyPE

 

of

 

USE

 

May

 

RESUlt

 

In

 

PREMatURE

 

faIlURE

 

of

 

tHE

 

UnIt

 

dUE

 

to

 

ExtREMEly

 

loW

 

REtURn

 

aIR

 

tEMPERatURE

 

and

 

ExPoSURE

 

to

 

coRRoSIvE

 

oR

 

vERy

 

dIRty

 

atMoSPHERES

Summary of Contents for GPG16 M Series

Page 1: ...ING This forced air central unit design complies with requirements embodied in The American National Standard National Standard of Canada ANSI Z21 47 CSA 2 3 Gas fired central furnaces WARNING PROP 65...

Page 2: ...any appliance Do not touch any electrical switch do not use any phone in your building Immediately call your gas supplier from a neighbor s phone Follow the gas supplier s instructions If you cannot...

Page 3: ...ese installation and operating instructions all local building codes and ordinances or in their absence with the latest edition of the National Fuel Gas Code NFPA54 ANSI Z223 1 and National Standard o...

Page 4: ...g material according to local codes Pre Installation Checks Carefully read all instructions for the installation prior to installing unit Ensure each step or procedure is understood and any special co...

Page 5: ...ngs building openings or openable windows must be maintained in accordance with the latest edition of the National Fuel Gas Code ANSI Z223 1 NFPA 54 Minimum horizontal clearance of 48 from the furnace...

Page 6: ...ir into the unit fresh air intake NOTE If the 36 minimum clearance is used on the control panel side of unit a flue extension kit needs be to installed to prevent flue gas recirculation See table belo...

Page 7: ...the unit must not be less than 60 Two spreader bars must span over the unit to prevent damage to the cabinet by the lift cables Spreader bars must be of sufficient length so that cables do not come in...

Page 8: ...ng from sharp edges follow national electrical code and all local codes and ordinances Do not route wires through removable access panels CAUTION Conduit and fittings must be weather tight to prevent...

Page 9: ...k connections control box note depending on the options installed the location of the components may vary in some models WARNING Failure of unit due to operation on improper line voltage or with exces...

Page 10: ...efer to unit wiring diagrams for thermostat or remote sensor connections GAS SUPPLY PIPING WARNING To prevent personal injury or death due to improper installation adjustment alteration service or mai...

Page 11: ...threads only Pipe joint compound must be resistant to the action of the fuel used 3 Use ground joint unions 4 Install a drip leg to trap dirt and moisture before it can enter the gas valve The drip le...

Page 12: ...to convert units to propane gas NOx screens must be removed before converting to LP Remove burner assembly and pull NOx screens from each burner tube When all the screens are out reassemble the burner...

Page 13: ...supply gas pressure is less than 11 0 w c or greater than 13 0 w c 6 All pipe connections should be sealed with a pipe thread compound which is resistant to the fuel used with the furnace A soapy wat...

Page 14: ...Checks procedure provides a step by step sequence which if followed will assure the proper startup of the equipment in the minimum amount of time Air balancing of duct system is not considered part o...

Page 15: ...Motor Adjust the CFM for the unit by changing the position of the low voltage leads on the terminal block TB1 Refer to Appendix A for blower performance at each speed tap Refer to Appendix D for maxi...

Page 16: ...16 Wiring Example...

Page 17: ...rmal manifold pressure for High fire is 3 5 w c on natural gas and 10 0 w c for propane gas Low fire natural gas 2 0 w c 6 0 w c low fire propane gas Minimum gas supply pressure is 5 0 w c for natural...

Page 18: ...Gas Only Check It is the responsibility of the contractor to adjust the gas input to the unit To measure the gas input use a gas meter and proceed as follows 1 Turn off gas supply to all other applian...

Page 19: ...speed will lower the temperature rise A slower blower speed will increase the temperature rise NOTE Blower speed MUST be set to give the correct air temperature rise through the unit as marked on the...

Page 20: ...prior to resetting this manual reset control WARNING To avoid property damage personal injury or death due to fire or explosion a qualified servicer must investigate the reason for the rollout protec...

Page 21: ...the compressor control circuits will be ready to respond to a subsequent call for cooling Refrigeration Performance Check Check that compressor RLA corresponds to values shown in Appendix B RLA draw c...

Page 22: ...remove the filter access panel on return side of the unit Cabinet Finish Maintenance Use a fine grade automotive wax on the cabinet finish to maintain the finish s original high luster This is especi...

Page 23: ...dicates an internal fault check power supply to unit for proper voltage check all fuses circuit breakers and wiring Disconnect electric power for five seconds If LED remains off after restoring power...

Page 24: ...ce 4 FLASH CODE If the primary limit switch opens the gas valve is immediately deenergized the induced draft and air circulating blowers are energized The induced draft and air circulator blowers rema...

Page 25: ...62 859 0 62 0 2 1901 912 0 66 0 4 1787 909 0 66 0 4 1824 966 0 70 0 6 1702 955 0 69 0 6 1737 1014 0 73 0 8 1625 1005 0 73 0 8 1658 1067 0 77 0 2 2132 954 0 91 0 2 2175 1014 0 97 0 4 2056 993 0 95 0 4...

Page 26: ...4 70 0 70 0 7 2 6 5 50 6 49 9 70 0 70 0 Power Supply Model Number Electrical Rating Compressor Outdoor Fan Motor Indoor Fan Motor Optional Electric Heat Optional Powered Convienience Outlet FLA Optio...

Page 27: ...CURB LOCATION EMBOSS FOR THRU THE BASE UTILITIES RETURN 11 X 25 SUPPLY 12 X 17 Horizontal Discharge Vertical Discharge NOTE Refer to IOD 7082 included in the literature pack for installing horizontal...

Page 28: ...28 APPENDIX D MIN MAX AIRFLOW UNIT HEAT RANGE HIGH FIRE RATE BTU HR HEATING MINIMUM SCFM COOLING MINIMUM SCFM MAXIMUM SCFM GPG1660140M41 HIGH 140 000 1615 1500 2500 AIR FLOW RANGE FOR HIGH STAGE...

Page 29: ...RD YL YL BL VMC A1 A2 LS RD RD BK BK YL YL BK BK PU PU BK BK RS BK BK BK BK LPS ALS GAS PLM GAS PLF GR GY PU PU BL BR TN PU PU PU BL BR TN VM L1 L2 T1 T2 VMC F3 F3 FB3 4 BK RD PK BL BR GR YL WH PU GR...

Page 30: ...30...

Page 31: ...31...

Page 32: ...o the feedback page GOODMAN BRAND AMANA BRAND GOODMAN BRAND AMANA BRAND PRODUCT REGISTRATION Thank you for your recent purchase Though not required to get the protection of the standard warranty regis...

Reviews: