GEK-99044
Chapter 6. Using the Maintenance Menu
6-5
Use the following procedure to select this option:
1.
While in the
HeadService
menu, press the (left) or (right)
menu browse pushbutton until
Dot Counts
is displayed in the
lower right corner of the LCD.
2.
Press the
Select
pushbutton to access the
Dot Counts
option. The
individual print head number will be displayed followed by the
number of times the individual print head has been fired. In the
example to the left, XX represents the print head number and
nnnnnnnnn represents a number. Use the (left) or (right)
menu browse pushbutton to locate the desired print head
counter.
3.
Press the
Select
pushbutton to reset the count.
Note
Repeat this section as often as necessary to reset a print head
counter.
Print Chart
This menu is used to print a graph of the number of times individual
print heads have been fired.
Use the following procedures to select this option:
1.
While in the
HeadService
menu, press the (left) or (right)
menu browse pushbutton until
Print Chart
is displayed in the
lower right corner of the LCD.
2.
Press the
Select
pushbutton to print the print chart.
CLR to Stop
will be displayed in the lower right corner of the LCD.
HeadService
Dot Counts
Select to Reset
XX:nnnnnnnnn
HeadService
Print Chart
Print Chart
CLEAR to Stop
PRINT CHART SAMPLE