51
2. Technical data
2.1.Basic version
Print
mechanism
Paper
Type of printing
Fixed head thermal line
Character representation
576 dots/Line, 8 dots/mm
Print speed approx.
15 line/s (standard text mode)
Character/line
48 characters
40 characters
24 characters
20 characters
Character height
2.5 mm at 48(40) characters
5 mm at 24 (20)characters
Character sets
ASC II, german,
french, danish,
norwegian,
swedish / finnish,
spanish, english, cyrillic
Service life
min. 10x10
6
Impulse or 50 km
Type
commercial grade,
document proof
thermal paper
Width
80 mm (+0 / -1 mm)
Length
approx. 14 m
(approx. 4.600 line
up to 48 characters per line)
Max. outer roll diameter
40 mm
Min. inner roll diameter
11,5 mm
Temperature
standard paper: 0 °C to 60 °C
6
This mode can be used to print a group of texts, triggered by a
single <CR> input, even if no variable data is required to be
inserted.
NOTE: Text No. 7 is only pre-programmed with a variable data field.
8.5. Examples for automatic text insert mode
Example 1:
Consignment
print-out, with
time & date,
marks and
weights
Data input:
10:15:33 15/10/03 <CR>1<CR> 123 <CR> 1 <CR> 1027<CR> 997 <CR> 30 <CR>
Actual Print-out:
Pre-stored texts
(„
T
“ = spaces reserved for
variable data)
10:15:33
15/10/2003
1
TTTTTT
Product Ref:
123
2
Product Ref:
T T T T T T
Operator No:
1
3
Operator No:
T T T T T T
Gross:
1027
kg
4
Gross:
T T T T T T
Nett:
997
kg
5
Nett:
T T T T T T
Tare:
30
kg
6
Tare:
T T T T T T
Six blocks of data are inserted and printed in sequence.
In this example, the IPP144-40 GE automatically adds date & time
from its own real-time clock using the „PRINT DATE / TIME-HEAD-
LINE“ menu option. Four blocks of variable data are sent to the printer.
Data input:
115<CR> 33.7<CR> 62.8<CR> 228.7<CR>
Actual Print-out:
Pre-stored texts
13.10.03
13:49:52
Metrix Electronics Ltd.
1
Metrix Electronics Ltd.
Rankine Road, Daneshill West
2
Rakine Road, Daneshill West
GB-Basingstoke RG24 8PP
3
GB-Basingstoke RG24 8PP
4
Test Number:
115
5
Test Number:
T T T T T T
- - - TEST RESULTS - - -
6
- - - TEST RESULTS - - -
Ambient Temp
33.7
°C
7
Ambient Temp
T T T T T T
°C
Burn-in Temp
62,8
°C
8
Burn-in-Temp
T T T T T T
°C
Nom. Supply
230 Vac
9
Nom. Supply
230 Vac
Actual
228.7 Vac
10 Actual
T T T T T T
Va c
Example 2:
Quality test
print-out, with
several
measured
value
Actual Printout:
Pre-stored texts
15.10.2003
10:34:53
Manufactured by::
1
Manufactured by:
2
Metrix Electronics Ltd.
3
Metrix Electronics Ltd.
Rankine Road, Daneshill West
4
Rankine Road, Daneshill West
GB-Basingstoke RG24 8PP
5
GB-Basingstoke RG24 8PP
__________________
6
_________________
7
T T T T T T
All the texts up to Text No. 6 (without variable fields) are printed. Text No. 7
(the first variable field) just prints a blank line. (If there was any variable
data sent before the <CR> this would be inserted and printed here.)
Example 3:
A simple way
to print a
group of texts
The print-out is 10 texts - 4 with variable data inserted and 6 without.
Data input: <CR>
Summary of Contents for IPP 144 - 40 G
Page 3: ......
Page 5: ......
Page 7: ...ter c ...
Page 9: ......
Page 11: ......
Page 13: ......
Page 15: ......
Page 17: ......
Page 19: ......
Page 21: ......
Page 23: ......
Page 25: ......
Page 27: ......
Page 29: ......
Page 31: ......
Page 33: ......
Page 35: ......
Page 37: ......
Page 39: ......
Page 40: ...39 The following character set is used ...
Page 41: ......
Page 43: ......
Page 45: ......
Page 47: ......
Page 49: ......
Page 51: ......
Page 53: ......
Page 55: ......
Page 57: ......
Page 58: ......
Page 59: ...Note ...
Page 60: ......