![GMP AirStream 89299 Operation And Maintenance Download Page 15](http://html1.mh-extra.com/html/gmp/airstream-89299/airstream-89299_operation-and-maintenance_2236379015.webp)
Page 15
Installing cable.
The machine is fitted with a range of controls to help the operator to install cable in the minimum time with the
least risk of causing damage to the cable or microduct.
These controls are identified and their function is described below.
Torque control:
This is controlled via the pressure regulator in the control housing. A higher pressure setting corresponds to
more available torque. Follow the + / - markings on the control knob and note the setting on the pressure
gauge. We recommend settings between 2 to 8 bar dependant on cable size.
Speed control:
The needle flow control valve restricts the motors exhaust and therefore adjusts the speed of the machine.
Turn the knob clockwise to decrease flow (speed) and counter clockwise to increase flow.
On/Off Motor Air Valve:
This ball valve controls air flow to the motor. Since it is between the motor and the pressure regulator, it al-
lows the operator to set the correct pressure before he/she begins installing. The valve (along with the flow
control valve) should always be closed before the air line is connected to the machine to prevent unwanted
and potentially dangerous operation.
Speed Distance indicator:
This device will measure and display the distance traveled by the cable and also the speed at which the cable
is traveling. To toggle between speed (‘tacho’) and distance (‘count’) modes press the right-hand (green) but-
ton on the counter face twice. Pressing this button once displays the current mode (either ‘count’ or ‘tacho’).
To reset the distance to zero press the left hand (red) button.
Note: It is only possible to reset the distance to zero if you are in ‘count’ mode. Pressing the reset but-
ton while in ‘tacho’ mode will do nothing.
Should it be necessary to replace the speed distance-measuring device please contact GMP.
Speed/
Distance
Indicator
Reset
Torque
Control
On/Off Motor
Air Valve
Speed
Control
Fiber
Air Valve
Air
Pressure
Motor Oiler
Adjustment
Oil Fill
Fiber Air
Pressure