![Glowworm GC 41 319 08 Installation And Servicing Instructions Download Page 5](http://html1.mh-extra.com/html/glowworm/gc-41-319-08/gc-41-319-08_installation-and-servicing-instructions_2234643005.webp)
5
221051B
5
SECTION
General
1
in wg
4.3
5.3
4.0
mbar
10.8
13.1
10.0
in wg
6.1
6.7
5.0
mbar
15.3
16.6
12.4
Btu/h
31,566
44,136
56,570
kW
9.25
12.9
16.58
Btu/h
37,500
50,000
62,500
kW
11.0
14.65
18.32
Btu/h
20,000
30,000
40,000
kW
5.86
8.79
11.72
in wg
2.7
3.8
3.3
mbar
6.8
9.4
8.1
Btu/h
30,000
40,000
50,000
kW
8.79
11.72
14.65
Btu/h
25,000
35,000
45,000
kW
7.33
10.25
13.19
Nominal
min
Heat
med
Input
max
(Gross)
Nominal
min
Heat
med
Ouput
max
Burner
min
Setting
med
Pressure
max
Space Saver
Space Saver
Space Saver
Range Rating
K - F - B
K - F - B
K - F - B
30
4 0
5 0
Btu/h
25,476
38,217
50,630
kW
7.47
11.2
14.84
Space Saver
Space Saver
Space Saver
Model
K - F - B
K - F - B
K - F - B
30
4 0
5 0
Lifting
25.0kg
25.0kg
25.0kg
Weight
(55lb)
(55lb)
(55lb)
Total
30.0kg
30.0kg
30.0kg
Weight (dry)*
(66lb)
(66lb)
(66lb)
Water
1.7 litres
1.7 litres
1.7 litres
Content
(0.37 gal)
(0.37 gal)
(0.37 gal)
Gas
Rc
1
/
2
Rc
1
/
2
Rc
1
/
2
Connection
(
1
/
2
BSPT)
(
1
/
2
" BSPT)
(
1
/
2
" BSPT)
Water
22mm
22mm
22mm
Connection
Compression
Compression
Compression
Electrical
240V~50Hz fused 3A max
supply
Internal
Fuse to BS4265 sheet 2. Type F1A
Fuse Rating
Power rating
55W
* Note: The weight of the water is negligible
Range Rating
The boiler is range rated and may be
adjusted to suit individual system
requirements, refer to the relevant
column of the table.
Data Table