![Glowworm GC 41 319 08 Installation And Servicing Instructions Download Page 24](http://html1.mh-extra.com/html/glowworm/gc-41-319-08/gc-41-319-08_installation-and-servicing-instructions_2234643024.webp)
24
221051B
24
SECTION
Installation
6
s t e p
9
Side Flue Boiler
Installation
Remove the appropriate blanking plate
on the casing and fit it to the rear flue
outlet.
2901
s t e p
10
s t e p
11
Remove and discard the fan rear
outlet extension from the fan by
releasing the clip.
Fit the fan side outlet extension,
supplied in the loose items pack.
Secure with the clip previously
removed.
KEYHOLE SLOT
REAR VIEW
BLANKING
PLATE
GASKET
FAN REAR
OUTLET
EXTENTION
FAN SECURING
SCREW
FLUE HOOD
ASSEMBLY
SECURING
SCREW
GASKET
RIGHT HAND
FLUE HOOD
ASSEMBLY
FAN SIDE
OUTLET
EXTENTION
LEFT HAND
FLUE HOOD
ASSEMBLY
Remove the fan assembly from the
fluehood assembly, by removing the
two screws.
Partially refit the securing screws into
the fan.
Turn the fan assembly to the required
flue outlet direction.
Fit the flue hood over the partially fitted
securing screws in the special key hole
slot sandwiching the gasket between,
take care not to damage the gasket.
Turn the flue hood in the direction
shown.