![Glowworm GC 41 319 08 Installation And Servicing Instructions Download Page 19](http://html1.mh-extra.com/html/glowworm/gc-41-319-08/gc-41-319-08_installation-and-servicing-instructions_2234643019.webp)
19
221051B
19
SECTION
Air Duct/Terminal and
Flue Duct Assembly
Locate the flue duct into the air duct/
terminal.
5
Flue Installation
s t e p
s t e p
11
12
Place the sealant from the loose items
pack onto the flue manifold.
Fully locate the flue manifold into the
air duct/terminal and flue duct assembly
as shown, making sure of the correct
alignment of the “TOP”s.
Drill two 3mm diameter holes
through the air duct/terminal and flue
manifold.
Secure the air duct/terminal to the flue
manifold with the two self tapping
screws supplied in the loose items pack.
It should now not be possible to remove
the manifold.
s t e p
13
3mm DRILL SIZE
2896
AIR DUCT/TERMINAL
ASSEMBLY
FLUE
DUCT
SEALANT
AIR DUCT/TERMINAL
AND FLUE DUCT
ASSEMBLY
FLUE MANIFOLD
5mm