17
8. SAFETY
ZONE
Before using the equipment, make sure that the perimeter of the work area
has been delineated according to that which is described in section 5.1, in
such a way so that a safe distance from other equipment and/or surrounding
walls has been maintained.
Never stand within the working area while the hydraulic power lift is
manoeuvring. Only manoeuvre the lift under visual supervision and with
utmost care.
Always make sure that the work area is free of any type of work equipment
or other obstacles.
The operator must always have an escape route available behind him/her.
As already highlighted under point 5.1, the hydraulic power lift’s operating
area (Safety Zone) must conform to the following characteristics:
1.
It must be at least 6.90 m long and 8.00 m wide;
2.
the hydraulic power lift must be located at the centre of this zone;
3.
The control unit (and consequently the operator when manoeuvring
the hydraulic power lift by means of the button panel), bust be located
at least 3.00 m from the lift’s structure (or rather, from outside of the
Safety Zone).
During raising and lowering operations, the Safety Zone must absolutely be
free of personnel, animals and any eventual objects.
Work must always be performed at a suitable height (MAX 1.300 mm) and
must never be performed beneath the vehicle or beneath the lift’s structure.
Summary of Contents for Quick Pull
Page 1: ......
Page 2: ......
Page 6: ...6 2 2 Quick Pull Hydraulic Power Lift encumbrance dimensions ...
Page 16: ...16 7 8 9 RIF CODE DESCRIPTION 7 GK3 CONTACTOR 8 GK4 TRANSFORMER 9 GK5 CIRCUIT ...
Page 25: ...25 17 ANNEXES ...
Page 26: ...26 ...
Page 27: ...27 ...
Page 28: ...28 ...
Page 29: ...29 ...
Page 30: ...30 ...
Page 31: ...31 ELECTRICAL SYSTEM SCHEME ...
Page 32: ...32 ELECTRONIC BOARD ...
Page 33: ...33 HYDRAULICS SYSTEM SCHEME ...
Page 36: ......
Page 37: ......