13
6.1.
Airdraulic connection
After having removed the relative cap, connect the flexible oil pressure tube
by coupling the double key connectors. Tighten the connectors appropriately
(do not tighten excessively) and check that there is no leakage or drawing
after a brief period of function.
Connect the compressed air tubes using the quick connectors.
Connect the control unit’s air intake tube to the mains system.
IMPORTANT
A dehumidifier with a lubricator must be installed upstream from the
control unit on the compressed air distribution system.
The lack of this device could result in damage to the pneumatic solenoid
valve and thereby compromise the arm opening/closing functionalities.
Make sure that all of the connections have been performed properly.
Even a single incorrect connection or lack of contact will inhibit the
equipment’s proper function.
After having checked the control unit’s oil level (see the amount
recommended by the manufacturer in the Technical Characteristics Table),
raise and lower the lift 2 or 3 times in order to allow the air bubbles to be
purged from the hydraulic circuit.
It is absolutely forbidden for the user to tamper with the pressure
relief valve, which has been calibrated by the Manufacturer.
Summary of Contents for Quick Pull
Page 1: ......
Page 2: ......
Page 6: ...6 2 2 Quick Pull Hydraulic Power Lift encumbrance dimensions ...
Page 16: ...16 7 8 9 RIF CODE DESCRIPTION 7 GK3 CONTACTOR 8 GK4 TRANSFORMER 9 GK5 CIRCUIT ...
Page 25: ...25 17 ANNEXES ...
Page 26: ...26 ...
Page 27: ...27 ...
Page 28: ...28 ...
Page 29: ...29 ...
Page 30: ...30 ...
Page 31: ...31 ELECTRICAL SYSTEM SCHEME ...
Page 32: ...32 ELECTRONIC BOARD ...
Page 33: ...33 HYDRAULICS SYSTEM SCHEME ...
Page 36: ......
Page 37: ......