20
11. WARNINGS
AND
PRECAUTIONS TO BE TAKEN
The Quick Pull must be used by personnel over the age of 18 years who has
been duly trained and authorized with respect to that which is provided this
manual.
The instruction, use and maintenance manual must be read carefully
before the installation and use of the lift and must be properly applied in all
of its parts.
It is forbidden to use the machine for lifting people.
Before performing raising and lowering manoeuvres, always make sure
that the joints and the structure are free of tools, rags and objects of
any kind. In the event of accidental blockage during descent, immediately
stop the manoeuvre by releasing the button, raise the lift, remove the
obstacle and resume the descent manoeuvre.
In the case of power cables (for lighting, hand tools, etc.) present within the
lift’s manoeuvring area, always make sure that these do not pass over
or rest upon the structure in order to prevent them from being cut and
thereby conducting electrical current throughout the machine’s metallic
structure. This check must always be performed before the lift is activated.
Always check the load visually, especially during lifting, making sure that
it does incline or shift in an improper or abnormal fashion. In such cases,
lower the lift to ground level and position the vehicle properly.
Clean the vehicle support surfaces well regularly, as dirt build-up could
result in the load sliding.
Make sure that the air pressure input to the pneumatic circuit is
calibrated between 8 and 10 bar.
Ensure that the electrical system is equipped with an automatic
circuit breaker before connecting the cable to the electrical panel.
Bring the load to ground level at the end of the working day. Do not
leave the lift fully loaded.
The hydraulic power lift’s maximum capacity is 2,500 kg.
The operator is required to wear Personal Protection Devices and to
take all the necessary measures and precautions to ensure his/her own
safety.
WARNING
The safety devices must not be tampered with. These must always
be in optimal condition.
Summary of Contents for Quick Pull
Page 1: ......
Page 2: ......
Page 6: ...6 2 2 Quick Pull Hydraulic Power Lift encumbrance dimensions ...
Page 16: ...16 7 8 9 RIF CODE DESCRIPTION 7 GK3 CONTACTOR 8 GK4 TRANSFORMER 9 GK5 CIRCUIT ...
Page 25: ...25 17 ANNEXES ...
Page 26: ...26 ...
Page 27: ...27 ...
Page 28: ...28 ...
Page 29: ...29 ...
Page 30: ...30 ...
Page 31: ...31 ELECTRICAL SYSTEM SCHEME ...
Page 32: ...32 ELECTRONIC BOARD ...
Page 33: ...33 HYDRAULICS SYSTEM SCHEME ...
Page 36: ......
Page 37: ......