Selecting Inside Thermostat:

 

1.Turn the ON/OFF switch to OFF position, and then turn the  
   thermostat rocker switch to 

INSIDE THERMOSTAT

 as  

   indicated below:

2.Turn the ON/OFF switch to ON position again, the heater will  
   work on the inside thermostat mode.

Risk of malfunction & Damage: You can not change the 
INSIDE/WALL THERMOSTAT when the heater is  
running, you must turn the ON/OFF switch to OFF and 
then select the INSIDE/WALL thermostat mode.

Selecting Wall Thermostat:

 

1.Turn the ON/OFF switch to OFF position, and then turn the  
   thermostat rocker switch to 

WALL THERMOSTAT

 as indicated  

   below: 

2.Turn the ON/OFF switch to ON position, the heater will work  
   on the wall thermostat mode.

Risk of malfunction & Damage: You must turn 

the ON/OFF switch to OFF before selecting  

INSIDE/WALL thermostat.

Remote Control

Insert the batteries into the remote control as shown below:

NOTE: 

Remove the batteries if the remote control is not to be 

used for a month or more. Batteries left in the remote may 
leak and cause damage. 
DO NOT MIX OLD AND NEW BATTERIES!  DO NOT MIX 
ALKALINE, STANDARD (CARBON-ZINC) OR RECHARGE-
ABLE (NICKEL-CADMIUM) BATTERIES!

Turning The Heater On

To turn the heater ON, switch on the circuit breaker, press the 
ON/OFF rocker switch to ON position, press the POWER button 
on the remote, the power indicator will turn on and display the 
room temperature.

Setting The Temperature (with the remote 
control)

Note:

 You need to select the thermostat to

 INSIDE  

THERMOSTAT

 and then set the desired temperature: 

Press the + button until the numeric temperature starts flashing. 
Press button again to increase the temperature or the – button 
to decrease the temperature. 
The heater will run on heating when the room temperature is 
equal to or lower than the setting temperature - 2

, and will 

turn off when the room temperature is equal to or greater than 
the setting temp2

The factory setting temperature is 70

, if the room temperature 

is lower or equal to 68

, the heater will run out heating and will 

turn off when the room temperature is higher or equal to 72

.

Note: If you set the thermostat switch to WALL  
THERMOSTAT, press the + and - button cannot set the  
temperature, the heater will run in ON or OFF heating  
according the wall thermostat setting temperature.

Setting HIGH/LOW Heating Mode

When the heater is running, press the MODE button to set the 
heater to run on HIGH or LOW heating. 
HIGH heating: 7500W 
LOW heating: 4700W 
 
Note: You can not set the HIGH/LOW mode when the room 
temperature is equal to or greater than the set temperature 
+2

, because the heater is OFF.

Setting The Timer (with the remote control)

1.Press the TIMER button until Set Time starts flashing.   
   The default value is 3 hours. 
2.Press the “+” button to increase the set time or the “–” button  
   to decrease the set time. The timer can be set from 1 to 12  
   hours. The timer will set and execute after the LED display  
   stops flashing. The heater will shut OFF automatically when  
   the set time is reached. 
3.To turn the timer OFF, press the TIMER button, and then  
   pressing the “–” button to set the time to 0. The timer feature  
   will turn off when the LED stops flashing. 

To turn off the heater, switch off the circuit breaker. 

The circuit 

breaker serves as the power source for the heater.

 

This heater includes a visual alarm to warn that parts of the 
heater are getting excessively hot. If the alarm flashes, immedi-
ately turn the heater OFF and inspect for any objects on or ad-
jacent to the heater that may cause high temperatures. DO 
NOT OPERATE THE HEATER WITH THE ALARM FLASHING. 
To reset the heater, switch the circuit breaker OFF. Wait five to 
ten minutes for the heater to cool down before turning the 
heater on again. 

Turning The Heater Off

Horizontal Downflow Unit Heater  

With Remote Control

Summary of Contents for 246726

Page 1: ...trol Model 246726 PLEASE READ ALL INSTRUCTIONS BEFORE USING THIS HEATER Table of Contents Important Instructions 2 Parts List 2 3 Specifications 3 Installing Instructions 4 5 Operating Instructions 5...

Page 2: ...this heater only as described in this manual Any other use not recommended by the manufacturer may cause fire electric shock or injury to persons 13 This product must be installed by a certified elec...

Page 3: ...240V Frequency 60Hz Amps 31A Watts 7500 4700 Kilowatts 7 5 4 7 Circuit Breaker Amp rating 40A Limited Warranty Years 1 Certification UL cUL Product Specification N O P Q R Parts List N Increase Temper...

Page 4: ...Materials Needed Not Included Regular Screwdriver Set Spanner Impact Drill with 12mm Drill Bit Wall Mounted Installation 1 This heater should be installed at least 8 feet 2 4 m from the floor and no...

Page 5: ...stat Wire Connector Affixed with insulating tape Wire not for use Black Red Heater Red Black Red Black D Insert wires into the Thermostat Outlet Box and screw up the thermostat knock out here E Cover...

Page 6: ...2 and will turn off when the room temperature is equal to or greater than the setting temperature 2 The factory setting temperature is 70 if the room temperature is lower or equal to 68 the heater wi...

Page 7: ...it breaker The unit should reset automatically after 10 minutes If the thermal cut off protection trips again consult a certified licensed electrician to determine the reason for overheating Problem P...

Page 8: ...a todas las instrucciones antes de utilizar este calentador Tabla de conexiones Instrucciones importantes 2 Lista de pieza 2 3 Especificaciones 3 Instrucciones de instalaci n 4 5 Instrucciones de oper...

Page 9: ...a o vapores y l quidos inflamables 12 Utilice este calentador s lo como se describe en este manual Cualquier otro uso no recomendado por el fabricante puede provocar incendios descargas el ctricas o l...

Page 10: ...0 4700 Kilowatts 7 5 4 7 Amperaje del Disyuntor Breaker 40A A os de Garant a Limitada 1 Certificaci n UL cUL Especificaciones del producto N O P Q R Lista de partes N Bot n de aumento de la temperatur...

Page 11: ...ador Herramientas materiales necesarios no incluidos Juego de destornilladores normales Llave inglesa Taladro de impacto con una broca de 12mm Instalaci n en la pared 1 Este calentador debe instalarse...

Page 12: ...a aislante el cable no se usa Negro Rojo Calentador Rojo Negro Rojo Negro D Inserte los cables en la caja de salida del termostato y enrosque el termostato Golpee aqu E Cubrir el termostato INSTRUCCIO...

Page 13: ...e sea igual o inferior a la temperatura de ajuste 2 y se apagar cuando la temperatura ambiente sea igual o superior a la temperatura de ajuste 2 La temperatura de ajuste de f brica es 70 si la tempera...

Page 14: ...reiniciarse autom ticamente despu s de 10 minutos Si el interruptor t rmico proyectiva se enciende de nuevo consulte a un electricista certificado para determinar la raz n del sobre calentamiento Pro...

Page 15: ...tivement les instructions avant d utiliser cet appareil de chauffage Tableau des connexions Instructions importantes 2 Liste des pi ces 2 3 Sp cifications 3 Instructions d installation 4 5 Instruction...

Page 16: ...en service ou entrepos s 12 Le chauffages ne doit tre utilis qu en suivant les instructions de ce manuel Toute autre utilit non recommand e par le fabricant risque de provoquer un incendie une lectroc...

Page 17: ...ilowatts 7 5 4 7 Classification d intensit du disjoncteur 40A Nombre d ann es de garantie limit e 1 Certification UL cUL Sp cifications du produit N O P Q R Liste des pi ces N Bouton d augmentation de...

Page 18: ...connexion d alimentation de chauffage Outils mat riels n cessaires non inclus Jeu de tournevis ordinaire Cl Perceuse percussion avec m che de 12 mm Installation murale 1 Ce chauffage doit tre install...

Page 19: ...ant fil non utilis Noir Rouge Chauffage Rouge Noir Rouge Noir D Ins rez les fils dans la bo te de sortie du thermostat et vissez le thermostat Enclenchement ici E Couvrez le thermostat INSTRUCTIONS D...

Page 20: ...ante est gale ou inf rieure la temp rature de r glage 2 et s arr tera lorsque la temp rature ambiante est gale ou sup rieure la temp rature de r glage 2 La temp rature de r glage d usine est 70 Si la...

Page 21: ...dre le disjoncteur Cette unit devrait se r initialiser automatiquement apr s 10 minutes Si la mise hors fonction de protection thermique se d clenche encore consultez un lectricien certifi pour d term...

Reviews: