INSTALLING INSTRUCTIONS

All Wiring procedures and connections shall be in  
accordance with the national and local codes having 
jurisdiction.

All wiring must be installed by a certified  

electrician according to the local electrical 

codes. The ceiling heater must be grounded in 
accordance with all national and local building 

codes.

To reduce the risk of fire, do not store or use 

gasoline or other flammable vapors and 

 liquids in the vicinity of the heater.

CONTENTS

Part

Qty.

Description









9









  Tilt adjustment knob 
  Rubber washer 
  Hex bolt M10 x 60mm L, zinc plated 
  Washer, 10mm, zinc plated 
  Spring washer 
  Nut 
  Expansion bolt 
  Wall hanger 
  Handle 

Prior to installation:

 

· 

Disconnect the main supply connection. 

· 

Supply cables shall be 8 AWG (8.3 mm2) copper wires. 

· 

The heater must be connected to individual branch circuit  

  protected by 40 Amp circuit breaker only. 

· 

Supply cables must be equipped with a dual pole circuit  

  breaker rating at least 240V 40A/pole as main cutoff  
  switch of power connection to the heater.

Tools/ Materials Needed (Not Included):

 

· 

Regular Screwdriver Set  

· 

Spanner 

· 

Impact Drill with 12mm Drill Bit

Wall Mounted Installation

1.This heater should be installed at least 8 feet (2.4 m) from the  
   floor and no closer than 1 foot (0.3 m) from any adjacent  
   surfaces or walls. This minimum distance must be maintained. 
2.Keep at least 4.5 inches (0.12m) from the back wall, regardless 
   of whether the wall mount bracket is used. 
3.Mark the drill-hole positions in the wall or ceiling for the  
   mounting bracket.  
4.Drill the required holes with diameter fitted to the anchor    
   provided for positioning the wall mount bracket.  
5.Insert the anchors.  
6.Attach the wall mount bracket to the wall or ceiling and secure 
   with mounting screws.

7.5 in

7.5 in

WALL MOUNT

CEILING MOUNT

7.Hook the unit to the wall mount bracket and let the unit hang  
   from the bracket.

8.Insert the screw through the mounting bracket and the heater handle.  
   Tighten the nut.

WALL MOUNT

CEILING MOUNT

9.Loosen the screw to remove the wiring compartment/connection cover  
   in the rear of the heater. There are three pigtail leads. Both Black (L1)  
   and Red one (L2) are for power connection; Green is for grounding  
   connection.

L1

L2

Black

Red

Green

remove 

this cover

Horizontal Downflow Unit Heater  

With Remote Control

Summary of Contents for 246726

Page 1: ...trol Model 246726 PLEASE READ ALL INSTRUCTIONS BEFORE USING THIS HEATER Table of Contents Important Instructions 2 Parts List 2 3 Specifications 3 Installing Instructions 4 5 Operating Instructions 5...

Page 2: ...this heater only as described in this manual Any other use not recommended by the manufacturer may cause fire electric shock or injury to persons 13 This product must be installed by a certified elec...

Page 3: ...240V Frequency 60Hz Amps 31A Watts 7500 4700 Kilowatts 7 5 4 7 Circuit Breaker Amp rating 40A Limited Warranty Years 1 Certification UL cUL Product Specification N O P Q R Parts List N Increase Temper...

Page 4: ...Materials Needed Not Included Regular Screwdriver Set Spanner Impact Drill with 12mm Drill Bit Wall Mounted Installation 1 This heater should be installed at least 8 feet 2 4 m from the floor and no...

Page 5: ...stat Wire Connector Affixed with insulating tape Wire not for use Black Red Heater Red Black Red Black D Insert wires into the Thermostat Outlet Box and screw up the thermostat knock out here E Cover...

Page 6: ...2 and will turn off when the room temperature is equal to or greater than the setting temperature 2 The factory setting temperature is 70 if the room temperature is lower or equal to 68 the heater wi...

Page 7: ...it breaker The unit should reset automatically after 10 minutes If the thermal cut off protection trips again consult a certified licensed electrician to determine the reason for overheating Problem P...

Page 8: ...a todas las instrucciones antes de utilizar este calentador Tabla de conexiones Instrucciones importantes 2 Lista de pieza 2 3 Especificaciones 3 Instrucciones de instalaci n 4 5 Instrucciones de oper...

Page 9: ...a o vapores y l quidos inflamables 12 Utilice este calentador s lo como se describe en este manual Cualquier otro uso no recomendado por el fabricante puede provocar incendios descargas el ctricas o l...

Page 10: ...0 4700 Kilowatts 7 5 4 7 Amperaje del Disyuntor Breaker 40A A os de Garant a Limitada 1 Certificaci n UL cUL Especificaciones del producto N O P Q R Lista de partes N Bot n de aumento de la temperatur...

Page 11: ...ador Herramientas materiales necesarios no incluidos Juego de destornilladores normales Llave inglesa Taladro de impacto con una broca de 12mm Instalaci n en la pared 1 Este calentador debe instalarse...

Page 12: ...a aislante el cable no se usa Negro Rojo Calentador Rojo Negro Rojo Negro D Inserte los cables en la caja de salida del termostato y enrosque el termostato Golpee aqu E Cubrir el termostato INSTRUCCIO...

Page 13: ...e sea igual o inferior a la temperatura de ajuste 2 y se apagar cuando la temperatura ambiente sea igual o superior a la temperatura de ajuste 2 La temperatura de ajuste de f brica es 70 si la tempera...

Page 14: ...reiniciarse autom ticamente despu s de 10 minutos Si el interruptor t rmico proyectiva se enciende de nuevo consulte a un electricista certificado para determinar la raz n del sobre calentamiento Pro...

Page 15: ...tivement les instructions avant d utiliser cet appareil de chauffage Tableau des connexions Instructions importantes 2 Liste des pi ces 2 3 Sp cifications 3 Instructions d installation 4 5 Instruction...

Page 16: ...en service ou entrepos s 12 Le chauffages ne doit tre utilis qu en suivant les instructions de ce manuel Toute autre utilit non recommand e par le fabricant risque de provoquer un incendie une lectroc...

Page 17: ...ilowatts 7 5 4 7 Classification d intensit du disjoncteur 40A Nombre d ann es de garantie limit e 1 Certification UL cUL Sp cifications du produit N O P Q R Liste des pi ces N Bouton d augmentation de...

Page 18: ...connexion d alimentation de chauffage Outils mat riels n cessaires non inclus Jeu de tournevis ordinaire Cl Perceuse percussion avec m che de 12 mm Installation murale 1 Ce chauffage doit tre install...

Page 19: ...ant fil non utilis Noir Rouge Chauffage Rouge Noir Rouge Noir D Ins rez les fils dans la bo te de sortie du thermostat et vissez le thermostat Enclenchement ici E Couvrez le thermostat INSTRUCTIONS D...

Page 20: ...ante est gale ou inf rieure la temp rature de r glage 2 et s arr tera lorsque la temp rature ambiante est gale ou sup rieure la temp rature de r glage 2 La temp rature de r glage d usine est 70 Si la...

Page 21: ...dre le disjoncteur Cette unit devrait se r initialiser automatiquement apr s 10 minutes Si la mise hors fonction de protection thermique se d clenche encore consultez un lectricien certifi pour d term...

Reviews: