Description of the heater thermostat (CR-)
1. Main switch (0/1).
The switch is situated on the heater.
2. Function key.
The function key has several uses:
• To link up the thermostat to the CT- re
-
mote control. See the section on linking
up.
• To make the thermostat receive signals
from CT-, or not.
• To show zone linking. The display will
show the zone number (1–16).
3. Lamp for radio reception.
When the green lamp is lit, the thermostat
is being regulated by CT-. When the lamp
is dimmed, the temperature can be regu-
lated using the and keys.
4. Regulating temperature locally.
If you wish to override CT- and set the
temperature by means of the thermostat’s
controls, the green lamp for radio recep-
tion must be off (using the “F” key). The
temperature may now be set using the
and keys, as desired.
5. Lamp for “working”.
The red lamp shows when the heater is
switched on. The thermostat makes adjust-
ments at periods of appr. 40 seconds. E.g.,
if the heater must work about 50% of the
time to maintain the temperature, the lamp
will be on for about 20 seconds and off for
20 seconds.
6. Display.
Shows the desired set temperature in °C.
7. Antenna.