35
Description of the under-floor heating thermostat (CFG)
1. Main switch (0/1).
Is used to switch the under-floor heating on
and off.
FI = internal, built-in sensor.
FE= external sensor (wall or floor).
2. Function key.
The function key “F” has several uses:
• To link up the thermostat to your CT-
remote control. See the section on linking
up.
• To make CFG receive commands from
the remote control or not.
• To show zone linking. The display will
show the zone number (1–16) for three
seconds.
3. Lamp for radio reception.
When CFG is linked to CT- and the green
lamp is lit, the thermostat is being regulated
by CT-. When the lamp is dimmed, the
temperature may be regulated on the
thermostat using the and keys.
4. Local regulation of temperature.
If you wish to regulate the thermostat us-
ing its own controls, the green reception
lamp must be dimmed (using the “F” key).
Using the and keys, you may set the
temperature as desired.
5. Lamp for “working”.
The red lamp lights when heating is on.
The thermostat regulates between two
temperature limits. Heating is turned on at
appr. 1°C below the set temperature, and
turned off at appr. 1°C over.
6. Display.
Shows the desired (set) room temperature,
or the desired floor temperature when a
floor sensor is used.