background image

Luminous  

 

Dimensions Luminous 1200 

L1230 a x 460 l x 180 p mm 

 

Dimensions Luminous 1800 

L 1890 mm x A 500 mm x P 180 mm 

 

Type 

Built-in 

 

Voltage 

220/240 V  

 

Frequency 

50 Hz 

 

Power 

1000 W

2000 W  

 

Weight Luminous 1200 

25 kg 

 

Weight Luminous 1800 

37 kg 

The product complies with the European Safety Standards EN60335-2-30 and the European Standard Electromagnetic 
Compatibility (EMC) EN55014, EN60555-2 and EN60555-3 These cover the essential requirements of EEC Directives 

2006/95/EC and 2004/108/EC. 

Summary of Contents for Luminous 1200

Page 1: ...20 240 V Frequency 50 Hz Power 1000 W 2000 W Weight Luminous 1200 25 kg Weight Luminous 1800 37 kg The product complies with the European Safety Standards EN60335 2 30 and the European Standard Electromagnetic Compatibility EMC EN55014 EN60555 2 and EN60555 3 These cover the essential requirements of EEC Directives 2006 95 EC and 2004 108 EC ...

Page 2: ...ammFire 2 years warranty please register your product at www glammfire com pt sobre garantia or complete your warranty card and send it to us along with a purchase copy to our address within 30 days after the pruchase For more information check the Warranty chapter ...

Page 3: ... 3 Installation 6 3 1 Mounting Methods 6 3 1 1 Flush mount 6 3 1 2 Surface mount 9 3 1 2 1 Luminous 1800 9 3 1 2 2 Luminous 1200 10 3 1 3 In wall Recessed only on Luminous 1200 12 4 Controls 14 5 Maintenance 16 6 Overall Dimensions 17 7 After Sale Service 18 8 Warranty 18 ...

Page 4: ...s quality product has been designed with preci sion and rigour that characterizes us to offer you pleasant and soothing moments Please read the instructions for use carefully and effective before using the appliance Keep this Manual in a safe place Please read this manual before using your appliance and keep it for future reference All presented warnings must be respected The information provided ...

Page 5: ... the room on their own unless constant supervision is provided Ensure that furniture curtains or other combustible material are positioned no closer than 1 metre from the applian ce In the event of a fault unplug the appliance Unplug the appliance when not required for long periods Although this appliance complies with safety standards we do not recommend its use on deep pile carpets or on long ha...

Page 6: ...o persons NOTE A 15 Amp 120 Volt circuit is required A dedicated circuit is preferred but not essential in all cases A dedicated circuit will be required if after installation the circuit breaker trips or fuse blows on a regular basis when the heater is operating Additional appliances on the same circuit may exceed the current rating of the circuit breaker 3 1 1 FLUSH MOUNTED CAUTION Two people ma...

Page 7: ...n Ensure that the 3 Position Switch is set to the Off position O and that the circuit on which the fireplace is to be installed has the power cut off at the service panel until installation is complete 3 Lift fireplace and insert into opening The fireplace s mounting trim should be flush against the wall Figure 3 4 Use bubble level supplied to level the fireplace within the framing Adjust as requi...

Page 8: ... Figure 6 6 4 Ensure the fireplace s 3 Position Switch is switched to the Off position O 6 5 If unit is not hard wired Plug fireplace into a 10 Amp 230 240 Volt outlet NOTE 1 A 13 Amp 230 240 Volt circuit is required A dedicated circuit is preferred but not essential in all cases A dedicated circuit will be required if after installation the circuit breaker trips or fuse blows on a regular basis w...

Page 9: ...ing bracket with the bubble level on the top on the wall so that the bubble on the level is centered between the two black lines 3 Mark the 4 mounting screw locations on the wall ensuring that the wall bracket stays level Figure 7 4 In locations where the screws are being installed only into drywall install the supplied wall anchors before installing the screw predrill if required 5 Secure the wal...

Page 10: ...or injury to persons always use a licensed electrician Ensure that the circuit on which the fireplace is to be installed has the power cut off at the service panel until installa tion is complete 3 Remove the partially reflective glass from the fire Lay fireplace on its back Remove Phillips screws from each of the two glass brackets figure 9 Remove glass brackets With one hand keeping pressure on ...

Page 11: ...Repeat if only two screws line up with a wall stud 8 Screw all four supplied 8 38 mm square head mounting screws and washers into the wall and or wall anchors leaving 6 5 mm of thread 9 Align chosen key holes with screws and hang fireplace on the wall Screw heads and washers will fit through keyho les and fireplace will slide down into place screws will slide into narrow part of keyholes 10 Tighte...

Page 12: ...lug in you may run the power cord out of the framed wall opening to an existing outlet or install an outlet on a nearby wall stud within the wall Hard wire the fireplace recommended AVISO Do not attempt to wire your own new outlets or circuits To reduce the risk of fire electric shock or injury to persons always use a licensed electrician Ensure that the 3 Position Switch is set to the Off positio...

Page 13: ...e framing Adjust as required 5 Drive four supplied mounting screws through the four mounting holes located in each corner of the fireplace chas sis into wall studs Figure 13 6 Refer to Front Glass Installation section for final installation procedures page 8 Figure 12 Figure 13 ...

Page 14: ...lour Themes are setting wich change the colour of the fuel bed there are eight diferente themes Theme 1 Theme 1 is a Demo mode this setting will scroll throught all of the colour settings you can Pause this demo mode by pressing th Brightness Button in which case the display will read I P to unpause press the Brightness Button in which case display will read I U Theme 2 8 Themes 2 8 are preset col...

Page 15: ...both 3 Dot button and 2 Dot on the unit and hold until beep is heard and display flashes To revert back repeat this action Ligar Desligar a opção de aquecimento Resetting the Temperature Cutoff Switch Should the heater overheat na automatic cut out will turn the whole unit off and it will not come back on without being reset It can be reset by turning the unit off at the main disconnect panel and ...

Page 16: ...can be removed by dusting lightly with a clean dry cloth To remove fingerprints or other marks the partially reflective glass can be cleaned with a damp cloth The partially reflective glass should be completely dried with a lint free cloth to prevent water spots To prevent scrat ching do not use abrasive cleaners Fireplace Surface Cleaning Use only a damp cloth to clean painted surfaces of the fir...

Page 17: ...GlammFire PAG 17 6 OVERALL DIMENSIONS Luminous 1800 Luminous 1200 ...

Page 18: ... fitted by an authorised service technician Use of spare parts other than those supplied by the manufacturer will invalidate the appliance warranty and must only be fitted by an authorised service technician IMPORTANT Registering your product does not require proof of purchase if it will be made on our website and must be based on the date of purchase It will be assumed that registration informati...

Page 19: ...tured under the strict Standard of the world recognized ISO 9001 2008 Quality As surance Certificate GlammFire products are designed with superior components and materials assembled by trained craftsmen who take great pride in their work Once assembled the complete fireplace is thoroughly inspected by a qualified technician before packaging to ensure that you the customer receive the quality produ...

Page 20: ...PT09097 E Recuperadores Pachinha Lda Zona Industrial da Lagoa Lote G1 4950 850 CORTES MONÇÃO PORTUGAL Tel 351 251 654 800 Fax 351 251 654 801 info glammfire com www glammfire com ...