background image

C 590T

www.contura.eu

Installation

instruction

Summary of Contents for C 590

Page 1: ...C 590T www contura eu Installation instruction ...

Page 2: ...ECLARED PERFORMANCE Essential characteristics Performance Harmonised technical specification Reaction to fire A1 WT Minimum distance to combustible material 100 mm to rear 480 mm to side Other safety distances according to the installation instructions Risk of falling embers Approved Emissions from combustion CO 0 06 NOx 112 mg m3 OGC 58 mg m3 PM 26 mg m3 Surface temperatures Approved Cleaning opt...

Page 3: ...on Read how to best light your stove in the lighting instructions The stove becomes very hot During operation certain surfaces of the stove become very hot and can cause burn injury if touched Also take heed of the strong heat radiated through the door glass Placing flammable material closer than the safe distance indicated may cause a fire Smoulder combustion can cause quick gas ignition with the...

Page 4: ... an authorised technician Contact one of our dealers who can recommend suitable fitters Building permission These main insructions may give guidance which would contravene national building regulations Please refer to supplementary instructions or ask your local authority for advice regarding building regulations Before installing a stove or erecting a chimney it is necessary for you to make a bui...

Page 5: ...REMOVAL How to remove the hearth surround Vermiculite Handle the vermiculite with care Lift the smoke baffle with one hand whilst removing the sides pieces Reinstall in reverse order How to remove the heat deflector ...

Page 6: ...nal diameter of the connection sleeve is 150 mm The stove requires a draft in the chimney of at least 12 Pa The draft is affected both by the length and area of the chimney and by how well sealed it is The minimum recommended chimney length is 3 5 m and suitable cross sectional area is 150 200 cm 140 160 mm in diameter A flue with sharp bends and horizontal routing reduces the draught in the chimn...

Page 7: ...t be selected In hot areas the duct should be insulated with 30 mm mineral wool covered with a moisture inhibitor plastic It is important that the lead in between the pipe and the wall or floor is sealed using jointing compound A 1 m length of condensation insulated ducting for combustion air is available as an accessory Through the external wall Indirect air supply through the external wall Throu...

Page 8: ...tances WHEN INSTALLING TURNTABLE OPTION the following installation distances do not apply See the separate installation instructions for turntable A height from floor to chimney connection upwards B height from floor to c c chimney connection rear C height from floor to air inlet D height from floor to lower edge of hatch A separate glass hearth plate accessory increases the connection height to t...

Page 9: ...10 10 VANADIU M No 7 CHROME 10 1 0 CH RO M E 2 1 3 73 GB Installing C 590T ASSEMBLY ...

Page 10: ...10 1 0 CH RO ME 1 0 1 0 C H R O M E 1 0 1 0 C H R O M E 4 6 5 7 74 GB ASSEMBLY ...

Page 11: ...8 9 75 GB ASSEMBLY ...

Page 12: ...the insert on the hearth plate and check the installation distance Connection to the chimney from the rear of the stove body is carried out prior to installing the soapstone When the connecting the chimney to the top of the stove body the soapstone surround must be installed first Remember to install the hot air grille before top connecting ...

Page 13: ...3 5 4 6 77 GB ASSEMBLY ...

Page 14: ...hat the installation is inspected by an authorised chimney sweep before the stove is used Also read the Lighting instructions before lighting for the first time Final inspection of the installation Position the supplied rating plate as illustrated ...

Page 15: ...1 1 2 2 1 2 2 1 3 4 79 GB Installing the lower cover ASSEMBLY ...

Page 16: ...off time It is important to open the damper at next lighting Otherwise the convection air is prevented from cooling the insert during the firing Installing the stone magazine With top connected chimneys the stone magazine and the damper must be installed before the chimney Stoves with fans must not be equipped with a convection damper Contura reserves the right to change dimensions and procedures ...

Reviews: