SUPPLY AIR/ACCESSORY
Supply of combustion air
When a stove is installed in a room, the demand for air supply to the
room increases. Air can be provided indirectly via a vent in the outer
wall or via a duct from the outside that is connected to the connector
on the underneath of the stove. The amount of air needed for
combustion is approx. 25m
3
/h.
The connector has an external diameter of 67 mm. When duct
routing further than 1 m the pipe diameter must be increased to 100
mm and a correspondingly larger wall vent must be selected.
In hot areas the duct should be insulated with 30 mm mineral wool
covered with a moisture inhibitor (plastic). It is important that the
lead-in between the pipe and the wall (or floor) is sealed using
jointing compound.
A 1 m length of condensation-insulated ducting for combustion air is
available as an accessory.
Through the external wall
Indirect air supply through the external wall
Through floor and foundation slab
Through floor and wall-and-cavity foundation
C 590T
In the back and floor plates there are knockouts
that must be removed to insert pipes or for air
supply if the stove is equipped with a lower hatch
and/or fan (accessory).
Installation variants
Leave a 40 mm gap between the condensation
insulation and the bottom of the stove.
Summary of Contents for C 590
Page 1: ...C 590T www contura eu Installation instruction ...
Page 9: ...10 10 VANADIU M No 7 CHROME 10 1 0 CH RO M E 2 1 3 73 GB Installing C 590T ASSEMBLY ...
Page 10: ...10 1 0 CH RO ME 1 0 1 0 C H R O M E 1 0 1 0 C H R O M E 4 6 5 7 74 GB ASSEMBLY ...
Page 11: ...8 9 75 GB ASSEMBLY ...
Page 13: ...3 5 4 6 77 GB ASSEMBLY ...
Page 15: ...1 1 2 2 1 2 2 1 3 4 79 GB Installing the lower cover ASSEMBLY ...