18
Mounting of audio control device
For installation protected from dripping and sprayed water,
mount the control device to a top-hat rail in the distribution.
The mains and bus connection is made via screw terminals.
The mains connection must be made via an all-pole mains
switch with at least a 3 mm contact opening.
The ventilation slits of the control device must not be blocked.
Technical data of audio control device
Primary rated voltage:
AC 230 V, 50 Hz
Secondary rated voltage: SELV 26 V DC ± 2 V
Secondary rated current: 160 mA continuous load
Overload deactivation from
approx. 350 mA
550 mA peak load (max. 5 seconds)
Power:
47 VA
Protection type:
IP 20
Screw terminals:
0.6 mm to 2.5 mm
2
door opener output:
12 V AC, 1.6 A
Power-on time
25% (max. 10 seconds ON,
door opener:
then 30 seconds OFF)
Contact load capacity
(relay output):
30 V AC, 2 A
Door opener time:
adjustable, 1 to 10 seconds
Operating temperature:
- 5 °C to + 45 °C
Dimensions:
6 modules, series inst. housing
Attention
Installation and mounting of electrical devices may only be
carried out by a qualified electrician.