Heat pump water heater
- 36 -
EN
•
open a hot water tap (e.g. bathroom, wash basin, etc.) to allow the water to flow out; when the water outflow
from the tap is constant the equipment will be full;
•
check that there are no leaks from the various hydraulic connections;
We recommend that you clean the pipes before laying them.
Only proceed with the electrical connection after performing this operation.
3.4
Electrical connection
WARNING: The equipment is already factory-wired and is equipped with a plug for the connection to
an outlet having appropriate electrical characteristics.
Verify that the mains voltage complies with the value specified in the label applied on the equipment,
and that the mains can supply the specified power.
To disconnect the equipment from the mains you need to use a two-pole switch complying with the EN standards
(contact opening 3mm, preferably equipped with fuses). The connection must be established by inserting the plug
into the appropriate outlet, that must comply with the regulations in force.
WARNING: Switching on the equipment when it is not filled with water will seriously damage the
refrigerating units and the electrical resistance.
WARNING: If the supply cable is damaged, it must be replaced by the manufacturer or by its technical
support service, or anyway by a person having a similar qualification, to prevent any risk
3.5
Fuse characteristics
Characteristics of the F1 fuse in case of replacement: F-5x20-16A
Summary of Contents for Futura 100 TS
Page 2: ... 2 ...
Page 23: ...Scaldacqua a pompa di calore 23 IT Fig 3 Fig 4 ...
Page 24: ...Scaldacqua a pompa di calore 24 IT ...
Page 44: ...Heat pump water heater 44 EN 8 Illustrations Fig 1 Fig 2 Distances from any surface ...
Page 45: ...Heat pump water heater 45 EN Fig 3 Fig 4 ...
Page 46: ... 46 APPUNTI NOTES ...
Page 47: ... 47 ...