5. Operation
5. Operation
5.5.4.2 Backup Settings
This section shows the parameters of the backup port.
Settings
Backup Settings
2015-02-23 19 35
Backup Voltage
:
B
ackup
Frequency
:
Voltage Droop
:
240.00V
60.0Hz
Disable
S E L E C T
=
< E N T >
D O N E
=
< E S C >
Figure 5.32 Backup Settings
There are three settings available in this section: Meter select, Storage Mode Select and
Battery Wakeup.
5.6.5 Storage Energy Set
Figure 5.33 Storage Energy Set
Settings
Srorage Energy Set
2015-02-23 19 35
Meter Select
Storage Mode Select
Y E S
=
< E N T >
N O
=
< E S C >
.38.
.39.
Battery Wakeup
Settings
Meter Select
2015-02-23 19 35
5.6.5.1 Meter Select
Figure 5.34
Storage Energy Set
1Ph Meter
Meter Type
:
Y E S
=
< E N T >
N O
=
< E S C >
E S C
U P
D O W N
E N T
This setting is used to select the meter type based on the actual configuration.
NOTE:
Select "1Ph Meter" if you were able to successfully install the meter that
comes with the inverter package.
The "3Ph Meter" is not available yet and is reserved for future development.
Select “No Meter” if you do not wish to have the meter or are unable to
properly install it.
Note: this limits the battery operating modes of the system..
5.6.5.2 Storage Mode Select
There are four optional modes:
1.Self use 2.Feed in priority 3.Backup 4.Off grid
Settings
Storage
Mode
Select
2015-02-23 19 35
Self use
Mode
:
Figure 5.35
Storage Mode Select