5. Operation
5. Operation
This function is used to select corresponding grid standards.
Please refer to the actual LCD setting for the grid standard options.
Figure 5.25 Select Standard
5.6.1 Select Standard
Settings
Select Standard
2015-02-23 19 35
Y E S
=
< E N T >
N O
=
< E S C >
UL-240V
Select Standard:
Press "UP" and "DOWN" to go through the list.
Press "ENT" to check the parameters, press "ENT" again to select the standard.
This function is used to start or stop the generation of the inverter (see Figure 5.26).
Figure 5.26 Set Switches
5.6.2 Switches
Settings
Switches
2015-02-23 19 35
ON
OFF
Y E S
=
< E N T >
N O
=
< E S C >
5.6.3 Battery Select
If the hybrid inverter is not connected to a battery, then select "No Battery" to prevent
alarms.
For the above compatible battery modules, only two parameters need to be defined:
* OverDischg SOC (10%~40%, default 20%)
--Inverter will not discharge the battery when the OverDischg SOC is reached.
Battery self-discharge is unavoidable, the SOC may go lower than the limit if the battery
is unable to charge for a long period of time.
* ForceCharge SOC (5%~10%, default 10%)
--To prevent the battery from going into sleep mode, when the ForceCharge SOC is
reached the inverter will charge the battery using power from either PV or the grid,
if permitted.
.34.
.35.
Press the UP/DOWN keys to select the standard (UL-240V, UL-208V, R21P3-240,
R21P3-208, ISONE240, ISONE208, MEX-CFE , User-Def, etc.).
Press the ENTER key to confirm the setting.
Press the ESC key to cancel changes and return to previous menu.
There are 6 settings for USA and CSA market, UL-240V, UL-208V, R21P3-240, R21P3-208,
ISONE240 and ISONE208. The default grid setting is UL-240V.
NOTE:
ON: AC Relay is ON.
OFF: AC Relay is OFF.
B-BOX HV
Figure 5.27 Battery Select
Battery Module:
NOTE:
Please refer to the battery compatibility list on the company website to
confirm the latest battery options available in the inverter firmware.
Connecting a non-compatible battery will void the inverter warranty.