SUPERVEGA EVO BATTERY ASPIRATOR 

is a surgical aspirator with the following electrica features : 14V 

 4A with AC/DC 

adapter mod. UE60-140429SPA1 of FUHUA (input: 100-240V

~ - 

50/60Hz

 

 - 100VA) or Internally powered equipment (Li-Ion 

Battery 14.8V

 

 5.2A) or with cigarette lighter adapter (12V 

4A).  

SUPERVEGA EVO BATTERY ASPIRATOR

 is a desk-

type electric suction unit for the aspiration of body liquids, oral, nasal and tracheal aspiration in adults or children. This device has 
been designed to offer ease of transport and continuous use, thanks to an electronic system that manages the power supply.

 

The 

large LCD display facilitates the use of the device and increases suction by adjusting the control buttons.   
The signal on the LCD screen, placed on the front panel, allows you to monitor the charge status of the Lithium battery. The lithium 
battery and the innovative Feedback system, which guarantees a smart use by automatically controlling and adjusting the suction 
power, allow the battery to increase its autonomy and decrease the noise produced. 
The "PROXIMITY" function allows the device to be activated/deactivated via an infra-red proximity sensor (detecting the presence 
of the hand from a distance of tenths of centimetres without touching the suction unit) and it prevents and avoids possible cross-
contamination between patients as they are treated in turns.  
Made of highly heat resistant, electrically insulated plastic material in conformity with the latest European safety standard, the 
product is supplied with a complete polycarbonate autoclavable jar with overflow valve. 

GENERAL WARNING 

READ INSTRUCTION MANUAL CAREFULLY BEFORE USE. 

THE DEVICE IS FOR USE BY QUALIFIED PERSONNEL (SURGEON / PROFESSIONAL NURSE / ASSISTANT) 

THE USE OF THE DEVICE AT HOME IS RESTRICTED TO AN ADULT IN FULL POSSESSION OF MENTAL FACULTIES AND / OR 

HOME CARERS 

THE INSTRUMENT MUST NOT DISASSEMBLED. FOR TECHNICAL SERVICE ALWAYS CONTACT 

GIMA S.p.A.

IMPORTANT SAFETY RULES 

1.

Check the condition of the unit before each use. The surface of the unit should carefully inspected for visual damage. 
Check the mains cable and 

do not connect to power 

if damage is apparent

;

 

2.

Before connecting the appliance always check that the electric data indicated on the data label and the type of plug used, 
correspond to those of the mains electricity to witch it’s to be connected; 

3.

Respect the safety regulations indicated for electrical appliances and particularly:

Use original components and accessories provided by the manufacturer to guarantee the highest efficiency and safety 

of the device; 

The device can be used only with the bacteriological filter;

Never immerge the appliance into water;

Do not place or store the aspirator in places where it may fall or be pulled into the bathtub or washbasin. In the event 
it is accidentally dropped, do not attempt to remove the device from the water whilst the plug is still connected: 
disconnect the mains switch, remove the plug from the power supply and contact the 

GIMA

 technical service 

department. Do not attempt to make the device work before it has been thoroughly checked by qualified personnel 
and/or the 

GIMA 

technical service department. 

Position the device on stable and flat surfaces  in a way that the air inlets on the back aren’t obstructed;

To avoid incidents, do not place the aspirator on unstable surfaces, which may cause it to accidentally fall and lead to a 
malfunction and/or breakage. Should there be signs of damage to the plastic parts, which may expose inner parts of 
the energised device, 

do not connect the plug to the electrical socket. 

Do not attempt to make the device work 

before it has been thoroughly checked by qualified personnel and/or the 

GIMA 

technical service department. 

Don’t use in the presence of inflammable substances such as anaesthetic, oxygen or nitrous oxide;

Don’t touch the device with wet hands and always prevent the appliance coming into contact with liquids;

Don’t leave the appliance connected to the power supply socket when not in use;

Don’t pull the power supply cable to disconnect the plug remove the plug from the mains socket correctly;

Store and use the device in places protected against the weather and far from any sources of heat. After each use, it is 

recommended to store the device in its own box away from dust and sunlight. 

Don’t use the device thoracic drainage.

In general, it is inadvisable to use single or multiple adapters and/or extensions. Should their use be necessary, you 
must use ones that are in compliance with safety regulations, however, taking care not to exceed the maximum power 
supply tolerated, which is indicated on the adapters and extensions. 

4.

For repairs, exclusively contact technical service and request the use of original spare parts.

Failure to comply with the above can jeopardise the safety of the device;

 

5.

Use only for the purpose intended. 

Don’t use for anything other than the use defined by the manufacturer. 

The manufacturer will not be responsible for damage due to improper use or connection to an electrical system not 
complying with current regulation. 

6.

The medical device requires special precautions regarding electromagnetic compatibility and must be installed and used in 
accordance with the information provided with the accompanying documents: the 

SUPERVEGA EVO

 device must be installed 

and used away from mobile and portable RF communication devices (mobile phones, transceivers, etc.) that may 
interference with the said device.  

Summary of Contents for SUPERVEGA EVO BATTERY ASPIRATOR

Page 1: ...0 Gessate MI Italy gima gimaitaly com export gimaitaly com www gimaitaly com PROFESSIONAL MEDICAL PRODUCTS Gima S p A Via Marconi 1 20060 Gessate MI Italy Made in Italy Instruction manual SUPERVEGA EVO BATTERY ASPIRATOR 230 V 28183 ...

Page 2: ...r immerge the appliance into water Do not place or store the aspirator in places where it may fall or be pulled into the bathtub or washbasin In the event it is accidentally dropped do not attempt to remove the device from the water whilst the plug is still connected disconnect the mains switch remove the plug from the power supply and contact the GIMA technical service department Do not attempt t...

Page 3: ...ormatives IMPORTANT INFORMATION FOR CORRECT DISPOSAL OF THE PRODUCT IN ACCORDANCE WITH EC DIRECTIVE 2012 19 UE RAEE The symbol on the device indicates the separated collection of electric and electronic equipment At the end of life of the device don t dispose it as mixed solid municipal waste but dispose it referring to a specific collection centre located in your area or returring it to the distr...

Page 4: ...t the battery provided with this product shall not be treated as household waste By ensuring these batteries are disposed of correctly you will help prevent potentially negative consequences for the environment and human health which could otherwise be caused by inappropriate waste handling of the battery The recycling of the materials will help to conserve natural resources At the end of their li...

Page 5: ...ting the said component Conical fitting the number of cycles of sterilization and the number of cleaning cycles is strictly linked to the employment of the said component Therefore after each cleaning cycle it is up to the final user to verify whether the fitting is suitable for reuse The component must be replaced if there are visible signs of decay in the material constituting the said component...

Page 6: ...evice is equipped with a Lithium Ion Battery which cannot be reached from the outside Only refer to GIMA technical service personnel to replace it The device should be checked at least once every 12 months by technical service Every 24 months it is compulsory to have a safety inspection and technical maintenance performed on the device ONLY USE BATTERIES RECOMMENDED BY GIMA USE OF BATTERIES OTHER ...

Page 7: ...ng adapter to the device with the appropriate connector and insert the power cable plug to the power socket To start the treatment press the ON OFF button and check its green back light When the device is switched on the LCD screen activates displaying a bar graph graduated scale and negative pressure value which must be set by the operator The negative pressure is set with keys and which are foun...

Page 8: ... cigarette lighter DC 12V Connect the device s external plug 12V to the ligther plug with the cigarette lighter cable Check the battery power status of the vehicle before the cigarette lighter cable Press the switch to start suction Press the switch to the I position to turn it on WARNING Only use the originally supplied or recommended replacement cigarette ligther cables view the chapter Importan...

Page 9: ...ed Battery operation guaranteed Fixed yellow back light During battery operation Intermediate status Battery not fully charged Battery operation guaranteed start the charge cycle upon activation of the red back light Fixed red back light During battery operation Low battery Start charge phase ATTENTION A long and continuous beep is produced during this signal to warn the operator about the low cha...

Page 10: ...he surgical SUPERVEGA EVO BATTERY ASPIRATOR is intended for use in the electromagnetic environment specifiedbelow The customers or the user of the surgical SUPERVEGA EVO BATTERY ASPIRATOR should assure that it s used in such an environment Emissions test Compliance Electromagnetic environment guidance Irradiated Conducted emissions CISPR11 Group 1 The surgical SUPERVEGA EVO BATTERY ASPIRATOR only ...

Page 11: ...itters and TV transmitters can not be theoretically and accurately foreseen To establish an electro magnetic environment generated by fixed RF transmitters an electro magnetic study of the site should be considered If the field intensity measured in the place where the device will be used surpasses the above mentioned applicable level of conformity the normal functioning of the device should be mo...

Page 12: ...not carried out by technical service RULES FOR RETURNING AND RAPAIRING UNDER NEW EUROPEAN RULES GIMA REQUIRES THE FOLLOWING PROCEDURES TO BECARRIEDOUT TO PROTECT THE INSTRUMENT ANDTHE SAFETY OF ALL WHO COME IN CONTACT WITH IT Before returning an instrument for repair the external surfaces and all accessories MUST be carefully disinfected with a cloth soaked in methylated spirits or hypochlorite ba...

Page 13: ...Gima S p A Via Marconi 1 20060 Gessate MI Italy gima gimaitaly com export gimaitaly com www gimaitaly com PROFESSIONAL MEDICAL PRODUCTS Gima S p A Via Marconi 1 20060 Gessate MI Italy ...

Reviews: