For transmitters rated at a maximum output power not listed above, the recommended separation distance d in metres 

(m) can be estimated using the equation applicable to the frequency of the transmitter, where P is the maximum output 

power rating of the transmitter in watts (W) according to the transmitter manufacturer.

NOTE 1 

At 80 MHz and 800 MHz, the separation distance for the higher frequency range applies.

NOTE 2 

These guidelines may not apply in all situations. Electromagnetic propagation is affected by absorption 

and reflection from structures, objects and people.

Warning

Active medical devices are subject to special EMC precautions and they must be installed and used in accordance with these guidelines.

Electromagnetic fields can affect the performance of the device, so other equipment used near the equipment must meet the appropriate EMC 

requirements. Mobile phones, X-rays, or MRI devices are possible interference sources, as they emit high-intensity electromagnetic radiation.

The  use  of  ACCESSORIES,  transducers  and  cables  other  than  those  specified,  with  the  exception  of  transducers  and  cables  sold  by  the 

MANUFACTURER of the the device as replacement parts for internal components, may result in increased EMISSIONS or decreased IMMUNITY of 

the ME EQUIPMENT or ME SYSTEM.

The device should not be used when they are close to or stacked with other equipment, if necessary, please observe and verify that they can 

operate normally in the configurations.

Devices or systems may still be interfered by other equipment, even if other equipment meets the requirements of the corresponding national 

standard.

The device requires special precautions for electromagnetic compatibility (EMC) and requires qualified personnel to install and use in accordance 

with the EMC information provided below.

The device should not contact the pins of connectors marked with an ESD warning symbol, unless electrostatic discharge precautions are used, the 

device should not connect to these connectors.

In order to avoid the accumulation of electrostatic charge, it is recommended to store, maintain and use the equipment at a relative humidity of 

30 % or more. The floor should be covered with ESD dissipated carpets or similar materials. In the use of the components, non-synthetic clothing 

should be wore.

In  order  to  prevent  electrostatic  discharging  to  the  ESD-sensitive  parts  of  the  device,  the  personnel  should  contact  the  metal  frame  of  the 

components or the large metal objects near the device. When using the device, especially when it is possible to contact the ESD-sensitive parts of 

the device, the operator should wear a grounded bracelet designed for ESD-sensitive devices. For more information on proper use, please refer to 

the instructions provided with the bracelet.

All potential users are advised to understand the ESD warning symbols and receive training on ESD precautions.

The most basic content of the ESD precautionary procedure training should include an introduction to electrostatic charge physics, voltage level 

in the conventional case, and damage to the electronic components when the operator with electrostatic charge contacts them. In addition, 

the methods for preventing electrostatic buildup, and the manner and reasons for the release of human body static electricity to the ground or 

equipment frame or the use of a bracelet to connect the human body to the equipment or the ground before establishing the connection should 

be described.

The following cable types must be used to ensure that they comply with interference radiation and immunity standards:

Name

Length (m)

Power adapter cable

1.5

GIMA WARRANTY TERMS

The Gima 12-month standard B2B warranty

Disposal: The product must not be disposed of along with other domestic 

waste. The users must dispose of this equipment by bringing it to a specific 

recycling point for electric and electronic equipment

Summary of Contents for 49880

Page 1: ... ψηφιακο πιεσομετρο زاهج ةبقارم طغض مدلا يمقرلا M49880 M Rev 0 10 22 PROFESSIONAL MEDICAL PRODUCTS Contect Medical System Co Ltd Adress No 112 Qinhuang West Street Economic Technical Development Zone Qinhuangdao Hebei Province People s Republic of China Made in China CONTEC08E GIMA 49880 Shanghai International Holding Corp Gmbh Europe Address Eiffestrasse 80 20537 Hamburg Germany Gima S p A Via Ma...

Page 2: ...oduct to our company Responsibility for our company Our company have the responsibility to provide qualified product which conform to company standard of this product Our company will provide the circuit diagram calibration method and other information at the request of the user to help the appropriate and qualified technicians to repair those parts designated by our company Our company have the r...

Page 3: ...nd the person who can t express oneself please use the device under the guidance of a doctor Otherwise it may cause accident or dissension Please do not use for any other purpose except BP measurement Otherwise it may cause accident or holdback Please use special cuff Otherwise it is possible that measurement result is incorrect Please do not keep the cuff in the over inflated state for a long tim...

Page 4: ...e manganese or alkaline batteries do not use batteries of other types Otherwise it may cause fire Do not mix old and new batteries and batteries of different types Otherwise it may cause battery leakage heat rupture and damage to Electronic Sphygmomanometer Please don t put wrong the positive and negative of battery When the batteries power exhausts replace with four new batteries at the same time...

Page 5: ...nd digital equipment connected to this device must be certified to IEC standards such as IEC60950 Information technology equipment Safety and IEC60601 1 Medical electrical equipment Safety and all equipment should be connected to in accordance with the requirement of the valid version of the IEC60601 1 1 system standard The person connecting the additional equipment to the signal input and output ...

Page 6: ...ur legs Advice Try to measure your blood pressure at the same time each day with the same arm and the same pose for consistency The high and low location of cuff will cause changes in measure results Do not touch the sphygmomanometer cuff and windpipe during measure Measurements should be taken in a quiet place and the body relax Remain still 4 5 minutes before measurement Do not talk and movement...

Page 7: ...ay be dangerous Follow the instructions of your physician Note Wait at least 4 5 minutes between measurements When repeatedly measuring the accurate blood pressure value may not be measured due to congestion in the arm Please measure after the blood flow is smooth When the screen displays Err the measure can t be carried out correctly Irregular pulse icon is displayed in the measurement results if...

Page 8: ...er Medical Device complies with Directive 93 42 EEC Authorized representative in the European community Class II applied Socket for power adapter Interface for connecting cuff Voice deactivation Voice activation Great movement when measuring Cuff tied correctly Artery indicator label CHAPTER 10 ERROR MESSAGE When the high pressure position appears Err and the low pressure position appears the erro...

Page 9: ...ion start before press the measurement button Stop using the device and contact us Cuff never deflation Stop using the device and contact us Air pressure error Deflation error Pull out the cuff to deflate Stop using the device and contact us Others Keep arm body still measure again No press value displayed or the value unaltered when cuff inflating Pull out the cuff to deflate Stop using the devic...

Page 10: ...hod Oscillometric method Working mode Automatic Operation mode Continuous operation Pressure Range 0 297 mmHg 0 39 6 kPa Measurement range Pressure SYS 30 270 mmHg 4 36 kPa DIA 10 220 mmHg 1 3 29 3 kPa Pulse 40 240 min Inflation 160 5 mmHg 21 33 0 67 kPa Overpressure protect 297 3 mmHg 39 6 0 4 kPa Resolution Pressure 1 mmHg 0 133 kPa Accuracy Static pressure 3 mmHg 0 4 kPa Error The BP value meas...

Page 11: ...elow The customer or the user of the device should assure that it is used in such an environment Immunity test IEC 60601 test level Compliance level Electromagnetic environment guidance Electrostatic discharge ESD IEC 61000 4 2 6 kV contact 8 kV air 6 kV contact 8 kV air Floors should be wood concrete or ceramic tile If floor are covered with synthetic material the relative humidity should be at l...

Page 12: ...ixed transmitters such as base stations for radio cellular cordless telephones and land mobile radios amateur radio AM and FM radio broadcast and TV broadcast cannot be predicted theoretically with accuracy To assess the electromagnetic environment due to fixed RF transmitters an electromagnetic site survey should be considered If the measured field strength in the location in which the device is ...

Page 13: ... the pins of connectors marked with an ESD warning symbol unless electrostatic discharge precautions are used the device should not connect to these connectors In order to avoid the accumulation of electrostatic charge it is recommended to store maintain and use the equipment at a relative humidity of 30 or more The floor should be covered with ESD dissipated carpets or similar materials In the us...

Reviews: