ENGLISH

The technical specifications may change without notice

CLEANING OF THE DEVICE

Use a soft dry cloth with not – abrasive and not – solvent detergents. To clean the device external parts always 

use a cotton cloth dampened with detergent. Don’t use abrasive or solvent detergents. Before carrying out 

any cleaning and / or maintenance operation, disconnect the appliance from the power supply, unplugging it 

or turning off the switch on the device.

 Particular care should be taken to ensure that the internal parts of the equipment do not get in 

touch with liquids. Never clean the equipment under water.

During all clearing operations use protection gloves and apron (if need be, also wear a face mask and glass-

es) to avoid getting in contact with contaminating substances (after each utilization cycle of the machine).

ACCESSORIES SUPPLIES

•  Complete aspiration jar 1000ml

•  Conical fitting 

•  Tubes set 6 mm x 10 mm

•  Hydrophobic and antibacterial filter

•  AC/DC adapter 

•  Power supply cord for ac/dc adapter

•  Cigarette ligther cable

On request, versions with a complete 2000ml jar are also available.

Antibacterial and hydrophobic filter: designed for a single patient with the aim of protecting patient and 

machine against infections cross. It blocks the passage of the liquids that come into contact with it. Always 

replace it if yes suspected to be contaminated and / or wetted or discolored. If the aspirator is used on patients 

in pathological situations not known and where it is not possible to assess any indirect contamination, replace 

the filter after each use. The filter is not designed to be decontaminated, disassembled and / or sterilized. 

In case the pathology of the patient and / or is knownwhere there is no danger of indirect contamination, we 

recommend replacing the filter after each work shift or otherwise every month even if the device is not used.

Suction catheter: Single-use device to be used on a single patient. Do not wash or re-sterilize after use. 

Reuse may cause cross infections. Don’t use after lapse of the sell-by date

Insulation Class (when used with an Internal battery)

Internally Powered Equipment

Insulation Class (when used with a car cigarette 

lighter cable)

Class II

Size

350 x 210 x 180 mm

Battery Holding Time

80 minutes

Battery Time Charge

240 minutes

Accuracy of Vacuum Indicator

± 5%

Working Condition

Room temperature: 5 ÷ 35°C 

Room humidity percentage: 10 ÷ 93 % RH 

Atmospheric pressure: 800 ÷ 1060 hPa

Conservation condition and Transport

Room temperature: - 25 ÷70°C 

Room humidity percentage: 0 ÷ 93% RH 

Atmospheric pressure: 500 ÷ 1060 hPa

Summary of Contents for 28243

Page 1: ...RADOR SUPER VEGA BATTERY ASPIRADOR SUPER VEGA BATTERY SSAK AKUMULATOROWY SUPER VEGA BATTERY ASPIRATOR SUPER VEGA BATTERY SUPER VEGA BATTERY M28243 M Rev 2 09 20 PROFESSIONAL MEDICAL PRODUCTS Gima S p...

Page 2: ...ilst the plug is still connected disconnect the mains switch remove the plug from the power supply and contact the GIMA technical service department Do not attempt to make the device work before it ha...

Page 3: ...in Home Care Keep all accessories of the device out of reach of children under 36 months of age since they contain small parts that may be swallowed 15 Do not leave the device unattended in places ac...

Page 4: ...rotecting patient and machine against infections cross It blocks the passage of the liquids that come into contact with it Always replace it if yes suspected to be contaminated and or wetted or discol...

Page 5: ...part of the container from secretions under cold running water and then clean every single part in hot water temperature not exceeding 60 C Once again carefully wash each single part using if necessar...

Page 6: ...order to replace it consult the technical staff authorised by the manufacturer USE ONLY THE RECOMMENDED BATTERIES FROM GIMA THE USE OF OTHER BATTERIES ARE NOT RECOMMENDED AND INVOLVING THE CANCELLATIO...

Page 7: ...nd must be connected to the spout on the vase lid with the float assembled inside over flow device The overflow device is triggered the float closes off the internal lid fitting when the maximum volum...

Page 8: ...hicle before the cigarette lighter cable Press the switch to start suction Press the switch to the I position to turn it on WARNING Only use the originally supplied or recommended replacement cigarett...

Page 9: ...lose proximity with adjacent to or on top of the medical device If such use is necessary and unavoidable special precautions should be taken so that the electro medical device functions properly in it...

Page 10: ...The SUPER VEGA BATTERY SUCTION UNIT is intended for use in the electromagnetic environment specified below The customers or the user of the SUPER VEGA BATTERY SUCTION UNIT should make sure that it s u...

Page 11: ...rmined by an elec tro magnetic study of the sitea could be lower than the level of conformity of each frequency interval b It is possible to check for interference in proximity to devices identified b...

Page 12: ...ransmitters with a maximum nominal output power not shown above the recommended separation distance in metres m can be calculated using the equation applicable to the transmitter frequency where P is...

Page 13: ...rectly you will help prevent potentially negative consequences for the environment and human health which could otherwise be caused by inappropriate waste handling of the battery The recycling of the...

Reviews: