0630-999-28c_04.2002.p65
0630-999/28c
SLM
2-16
D
E
Procedure
1.
Staybar installation in the door wing (see instructions 0630-
999/33). Wings from the Schwarzenburg factory are supplied
with the staybar already mounted.
2.
Mount the locking PCB resp. adjust the function (see pages 3
and 4).
3.
Mount the wings to the drive unit and adjust them according
to the assembly guidelines for the respective drive unit.
4.
Mount the locking sheet resp. the locking plate (see pages
5...7).
5.
Mount resp. adjust the staybar locking drive unit (see pages
8...13).
6.
Check:
- Positions of the limit stop switches.
- Dead center of both final positions.
- Manual emergency operation: is the locking
lever pulled to the dead center in both final
positions?
7.
Mount the manual emergency mechanism (see instructions
0630-999/29).
8.
Mount the monitoring unit for the door and the locking (if
existing: see instructions 0630-999/32).
9.
Mounting the stop piece (see page 14).
10. Commissioning (see page 16).
Vorgehen
1.
Stangeneinbau in Türflügel (siehe Anleitung 0630-999/33).
Bei Flügeln ab Werk Schwarzenburg ist diese bereits mon-
tiert.
2.
Verriegelungsprint montieren resp. Funktion einstellen (siehe
Seiten 3 und 4).
3.
Flügel in Antrieb montieren und einstellen gemäss Montage-
richtlinien des entsprechenden Antriebes.
4.
Verriegelungsblech resp. Verriegelungsplatte montieren (sie-
he Seiten 5...7).
5.
Stangenverriegelungsantrieb montieren resp. einstellen (sie-
he Seiten 8...13).
6.
Kontrolle:
- Endschalterstellungen.
- Totpunkt beider Endstellungen.
- Handnotbedienung: Wird Verriegelungshebel
in beiden Endstellungen in Totpunkt gezogen?
7.
Handnotbedienung montieren (siehe Anleitung 0630-999/
29).
8.
Tür- und Verriegelungsüberwachung montieren (wenn vor-
handen: siehe Anleitung 0630-999/32).
9.
Anschlag montieren (siehe Seite 14).
10. Inbetriebsetzung (siehe Seite 16).