Installation
Page 14
MDE-2597L Gilbarco® Security Module (GSM) PA0258XXXXXXX Installation and Service Instructions · January 2010
6
For Q13698-03 power supplies, perform the following:
• Connect Q11121-01 Cable to the power supply.
• Plug cable into the power outlet.
For applications that do not have a NEMA 5-15 style outlet, the customer must supply a
connector and attach it to the end of a Q11736-01 Cable.
7
Turn on power to the Controller.
Note: Power must be applied to the GSM before it is applied to the Controller.
8
Verify the Passport POS system programming by checking for the following:
• Correct addresses Poll/Cluster/Select.
• Correct number of terminal IDs.
• Correct terminal IDs.
• Correct terminal address.
• Correct device type.
9
Contact the network for verification of parameters and station start up.
10
Observe the CRIND device display.
• If the CRIND device initiation is successful, you see a prompt requesting card insertion
on the display once the start up and initiation are complete.
• If the CRIND device displays OUT OF SERVICE or ONE MOMENT PLEASE, open the
G-SITE POS system shift.
• If the CRIND device displays PLEASE PAY INSIDE and beeps, it implies that the
third-party controller is not polling the CRIND device.
11
Using permanent ink marker write the month, day, and year of installation in block letters on
the front product label (see
).
12
Verify correct debit card processing by attempting a debit card transaction at the CRIND
device. Refer to
.
Connecting the GSM to Passport (V8.02 or Later)
To connect the GSM to the Passport system, proceed as follows:
1
Connect a 9-pin RPCI Gender Mender (Q13180-04B) to the GSM (see
on
2
Connect one end of a CAT-5 Cable (Q13482-XX) to the 9-pin Gender Mender (Q13180-04B)
and run the other end to the Enhanced Dispenser Hub Device.
3
At the Enhanced Dispenser Hub, connect the loose end of the CAT-5 Cable to a 9-pin COM
Gender Mender (Q13180-20B).
4
Connect the 9-pin Gender Mender (Q13180-20B) to an RJ-45 to DB-9 Male Cable Adapter
(M09747B010), or attach Q13180-20B to an Enhanced Dispenser Hub COM Gender Mender
(Q13180-63B). Q13180-63B will be attached to the Enhanced Dispenser Hub with a
Q13480-XX CAT-5 Cable.