MDE-2597L Gilbarco® Security Module (GSM) PA0258XXXXXXX Installation and Service Instructions · January 2010
Page 3
Introduction
Model Number Breakdown for the GSM
PA0258 0 0 or 1 XXXXX
Basic Model Number
0 - Source Voltage 90-260 VAC 50/60 Hz
0 - Operating Tempe50 ºF (+10 ºC) to +104 ºF (+40 ºC)
~ OR ~
1 - Operating Temperature -22 ºF (-30 ºC) to +158 ºF (+70 °C)
Customer and Version Identification (for example, 00BPS = BUYPASS)
Glossary
Download
Data sent from the host computer to the Controller. A download may be required before the
Controller can process debit cards.
Factory Start Up Date
Date when the GSM’s internal battery is enabled and encryption keys injected. Factory start up
date is recorded on a label affixed to the GSM housing. Upon receipt, the GSM must be
maintained under power to retain programming. If the internal battery is allowed to discharge
completely, the GSM will no longer be usable.
Note: GSMs are no longer remanufactured.
Injected Key Serial Number
A serial number injected by Gilbarco that uniquely identifies the GSM to the network host. It
is permanently erased if the GSM housing is opened or if the internal battery is allowed to
discharge completely. The POS system can interrogate the GSM for the injected key serial
number and pass it to the network host.
Install Date
Date when the GSM was installed to work with the host network.
Environmental Requirements
Parameter
Part Number
Values
Operating Temperature
PA025800XXXXX
+50 ºF (+10 ºC) to +104 ºF (+40 ºC)
PA025801XXXXX
-22 ºF (-30 ºC) to +158 ºF (+70 °C)
Relative Humidity
0% to 95% (Non-condensing)
Storage Temperature
-22 ºF (-30 ºC) to +176 ºF (+80 ºC)