MDE-2597L Gilbarco® Security Module (GSM) PA0258XXXXXXX Installation and Service Instructions · January 2010
Page 17
Installation
3
With the power off, connect the Power Supply Cable and the cable from the site controller into
the relevant ports at the rear of the GSM (see
).
Figure 6: Connecting the Power Supply Cable
Power Supply Cable
Cable from SBC or
Interface Board
The installation of the GSM in the SMART CRIND is complete.
Removing the GSM from Service
To adhere to the American National Standards Institute (ANSI)/International Organization for
Standardization (ISO) PIN key management security guidelines, the security regulations
mandated by the networks require that all cryptographic devices removed from service have
their encryption keys erased/destroyed.
As a result, it is necessary to erase the encryption key(s) maintained in the GSM when it is
removed from service.
This procedure renders the GSM unusable. Once performed, the GSM cannot be
placed back into service.
CAUTION
To remove the GSM from service, proceed as follows:
1
Disconnect the GSM Communications Cable from the Controller.
2
Remove the security label covering the screw on the end of the GSM opposite the Status LED.
3
When the GSM is powered up, remove the screw and discard.
Note: This process destroys the encryption key(s) in the GSM. The GSM is no longer usable.