MDE-5265E BRCM2.x Installation and Upgrade Instructions · April 2021
Page 3
Introduction
Theory of Operation
Note: For site connectivity diagrams, refer to
, and
If the upgraded D-Box or factory-shipped BRCM2.x ends in “12” or “22”, they include
two-wire distribution boards, allowing the communication to the dispenser/pump(s) to occur
over the current loop(s). The lid portion of the BRCM2.x assembly contains the high-speed
signal source that is merged with the dispenser/pump or CRIND
®
current loop.
For Passport
™
Point of Sale (POS), the BRCM2.x or upgraded D-Box will be communicating
over the existing current-loop connection.
For non-Passport POS, the BRCM2.x or upgraded D-Box will be communicating over the
dispenser/pump current-loop connection. Identify the D-Box or D-Box boards communicating
to the dispensers/pumps and mark those wire sets.
Note: Do not change the CRIND wiring.
Like previous D-Boxes, the BRCM2.x or upgraded D-Box will use D-Box boards. In a dual
board solution, the boards may have the following configurations:
• One board talking dispenser/pump or CRIND protocol message streams and another board
independently talking dispenser/pump or CRIND protocol message streams.
• Two boards communicating to up to 16 dispensers/pumps using the same message stream
(viable for CRIND communications only).
Site Connectivity Diagrams
shows a non-EMV Passport configuration. Current loop boards are required in the
BRCM2.x (model numbers ending with “12” or “22”). For additional details on this
configuration, refer to
on
. The PA0435 models has a single combined D-
box and a field wiring board; for more detail on this configuration, refer to
.
Figure 2: Passport (Expandable to Dual Boards)
Passport
BRCM2.x
DCM2.x board,
configured in
MOC mode
Ethernet
®
Two-wire with
CRIND Protocol
CRIND
Two-wire +
High-speed
show a non-EMV generic configuration. For this
configuration, the model number must end with
22
. For additional details on this
on
. The PA0435 models has a single combined D-
box and a field wiring board. The CCP board DCM2.x is also replaced with HCM board; for
more information on this configuration, refer to
on