4.
Ground
Caution
: Use a UL/IEC/EN 60950-1 certified power supply to connect to a DC converter,
and a #14 AWG (for -36 VDC to -72 VDC PSU) wire to connect to a DC PSU.
Attention
: Utilisez une alimentation certifiée UL/IEC/EN 60950-1 pour le connecter à
un convertisseur CC et un câble AWG #14 (pour -36 VDC à -72 VDC) pour vous
connecter à une alimentation CC.
Replacing Fans
Fans are field-replaceable. If a fan fails, you can replace it. Identify the fan that failed, and
replace it with a working fan using the procedures in this section.
To remove a fan:
1. Locate lever and handle as shown below:
2. Push lever towards handle.
3. Pull on handle to remove the fan from the slot.
To insert a fan:
1. Place fan in empty slot.
2. Use handle to slide fan into slot.
3. When fan is fully inserted, it locks in place.
Connecting Serial Console and Mgmt Ports
To make basic connections (serial console and Mgmt ports):
1. Locate the DB9-to-RJ45 serial cable provided with the GigaVUE TA Series TA Series
node. This cable is called a
console cable
.
Contents