2. Remove the protective shipping covers and screws. Save the protective shipping
covers and replace the screws in the holes on the system so that they are easily
saved in case you need to ship the system again.
3. Next, select a suitable location for the rack unit that will hold the GigaVUE TA Series
Traffic Aggregation node. Choose a location that is clean, dust free, and well
ventilated. You will need access to a grounded power outlet. Avoid areas where
heat, electrical wire, and electromagnetic fields are generated.
4. Plan for enough clearance in front of a rack so you can open the front door
completely (approximately 25in) and enough clearance in the back of the rack to
allow sufficient airflow.
Rack Mounting GigaVUE-TA25E
The GigaVUE-TA25E consists a Rack mounting kit which has 2 front-post brackets, 2 rear-
post brackets, 20 screws, and 2 ear-locking screws. To rack mount the chassis do the
following:
Attach the Brackets
1. Attach each of the front- and rear-post brackets to the node using four of the
included bracket screws.
2. Use the screws and cage nuts supplied with the rack to secure the node in the rack.
Contents
22
GigaVUE-TA25E Hardware Installation Guide