54
11
Status display
Errors
Display: "F" and code
Status
code
Description
Measures to solve the problem
Terminals X2.1 – X2.2 open.
Slack-wire/pedestrian contact open.
Check door safety switch.
Check the connection cable is proper fitted.
DES safety circuit open.
Emergency manual operation activated.
Motor thermal protection tripped.
Check emergency manual operation.
Check for overload or stalling of the drive unit.
Terminals X3.1 – X3.2 open.
Emergency Stop activated.
Check Emergency Stop.
Check the connection cable is proper fitted.
"WSD" wireless safety edge door module
batteries discharged.
Change "WSD" door module batteries.
Voltage monitored circuit – high resistance.
Open and close pedestrian door.
Check resistance.
Check pedestrian door installation.
Check Mains Supply
X2.1 – X2.2 Entry sense input faulty.
Switch control off and on.
Check Mains Supply.
Replace control if necessary.
Batteries in the "WSD" door module.
Change "WSD" door module batteries.
No safety edge system detected.
Check safety edge system wiring.
Check the "WSD" is functioning.
Terminals X6.1 – X6.2 open.
Photo cell obstructed.
Check alignment of the photo cell.
Check connection cable.
Replace photo cell if necessary.
Maximum number of consecutive
safety edge activations. (Parameter 2.5)
(Only with automatic closing)
Obstacles in the door travel path.
Check the safety edge system is functioning.