39
Integrated "WSD" wireless safety device
For evaluating the safety edge system and/or door safety switch without spiral cable. For
initial operation, see "Teach-in of the WSD door module".
Usable safety devices
Safety edge systems
8K2 resistor evaluation
Optical safety edge system (low-power sensors only)
Door safety switch
Slack-wire/pedestrian door switch
Crash switch with NC contact
Note!
▶
For description and adjustment of the safety device, see X2
Important!
•
If the battery is low, fault indication "F1.9" appears and control changes to "hold-
to-run" door operation
•
If battery is fully discharged fault "F1.6" is displayed and door movement is not
possible
X3: Emergency stop
Connection of an emergency stop button as per EN 13850 or safety device to prevent
trapping i.e. High level device to detect person riding on the door. If activated, fault indication
"F1.4" appears.
Note!
•
With FI drives, only the drive unit is de-energised by the emergency stop