41
X4: Automatic closing Off/On
Connect a key switch, time clock or similar to terminals X4/1 and X4/2 to turn off and on the
time delay to close function ”2.3”. (N/O – time to close ON, N/C – time to close OFF).
X5: Control device
Warning!
•
"Hold-to-run" door operating mode:
The person operating the door must be in the vicinity of the door and have full
view of the door during its entire movement.
“0.1” operating mode – “3” only the control unit mounted push buttons operate the door in
“Hold-to-run” mode if the safety edge or photo beam fails.
“0.1” operating mode – “4” the control unit mounted push buttons and remote connections to
terminals X5 operate the door in “Hold-to-run” mode if the safety edge or photo beam fails.
Note!
▶
Link X5.1 to X5.2 if a stop button or other normally closed device is not connected
▶
Read"X5 control device" description