10
Functional description
X: 24 V DC voltage supply
Connection of external devices such as photo cell, radio receiver, relay, etc. via the 24 V and
GND terminals.
Caution - Damage of components!
•
Total current consumption of external devices: maximum 350 mA
X1: Control mains supply line and external supply
Control mains supply line
Connection via terminals X1/1.1 to X1/1.4 and PE
Different mains supply connections: 3 N~ , 3~, 1 N~ for symmetrical and asymmetrical
motors
Note!
▶
Pay attention to the "Mains supply connection" and "Mains supply connection to
control" descriptions
External supply 230V AC
Supply for external 230V AC external devices such as photo cell, radio receiver, relay, etc.
via terminals X1/1.8 (neutral) and X1/1.9 (live).
Note!
•
230V AC Supply of external devices is only available when the incoming mains
supply is 3-phase with Neutral 400V or 1-phase 230V symmetrical connection
(See page 12)
•
Fusing via F1, micro-fuse 1.5 A time-delay