background image

Georg Fischer Signet LLC, 3401 Aero Jet Avenue, El Monte, CA 91731-2882 U.S.A. • Tel. (626) 571-2770 • Fax (626) 573-2057
For Worldwide Sales and Service, visit our website: www.gfsignet.com • or call (in the U.S.): (800) 854-4090
For the most up-to-date information, please refer to our website at www.gfsignet.com

3-8250.090-2 Rev. H  01/13   English 

 © Georg Fischer Signet LLC 2013

Ordering Information

Mfr. Part No. 

Code 

 

Description

3-8250-2 

159 000 766 

Level Transmitter, Field Mount

3-8250-2P 

159 000 767 

Level Transmitter, Panel Mount

3-8059-4 

159 000 772 

External 4-Relay Module

3-8059-4AC 

159 000 773 

External 4-Relay Module with Power Supply

Note: 

When using the 8059-4 or 8059-4AC, only relays 1 and 2 can be utilized with the 

fl

 ow instrument.

Accessories

Mfr. Part No. 

Code 

 

Description

3-8050   

159 000 184 

Universal mounting kit

3-8050.395 

159 000 186 

NEMA 4X Back Cover

3-8052   

159 000 188 

3/4” Integral mounting kit

3-8050.396 

159 000 617 

RC Filter Kit (for relay use), 2 per kit

3-0000.596 

159 000 641 

Heavy Duty Wall Mount Bracket

3-9000.392 

159 000 368 

Liquid-tight connector kit, 3 sets, 1/2 in. NPT5

3-9000.392-1 

159 000 839 

Liquid-tight connector kit, 1 set, 1/2 in. NPT5

3-9000.392-2 

159 000 841 

Liquid-tight connector kit, 1 set, PG 13.5

7300-7524 

159 000 687 

7.5W 24V Power Supply

7300-1524 

159 000 688 

15W 24V Power Supply

7300-3024 

159 000 689 

30W 24V Power Supply

7300-5024 

159 000 690 

50W 24V Power Supply

7300-1024 

159 000 691 

100W 24V Power Supply

Summary of Contents for Signet 3-8250-2

Page 1: ...ble and reversible Max loop impedance 50 max 12 V 325 max 18 V 600 max 24 V Update rate 300 ms Output accuracy 0 03 mA Relay outputs 2 sets mechanical SPDT contacts Software supports 2 additional rela...

Page 2: ...ure instrument temporarily with tape from front or grip from rear of instrument DO NOT RELEASE 5 Press quick clips outward and remove 2 1 Terminals 11 13 Digital S3 L The 2450 sensor and External Rela...

Page 3: ...el 1 4 to 20 mA in Channel 2 4 to 20 mA in System Pwr Loop System Pwr Loop AUX Power AUX Power System Pwr Loop System Pwr Loop AUX Power AUX Power Loop Input 4 to 20 mA System Pwr Loop System Pwr Loop...

Page 4: ...menu if the sensor is located at Z Level L The distance from Z to surface of fluid displayed as Level by transmitter L 0 O 0 Z SLOC L 0 O 0 Z SLOC L 0 SLOC O 0 Z 2450 Pressure Sensor Location and Offs...

Page 5: ...ted at each transition point in the vessel shape for example at custom point 9 where the shape changes from a cylinder to a cone The more complex sections should be defined with more points Notice tha...

Page 6: ...to change display selection Output settings cannot be edited from the VIEW menu When using the CALIBRATE or OPTIONS menus the ProcessPro will return to the VIEW menu if no key is pressed for 10 minut...

Page 7: ...g Procedure Step 1 Press and hold ENTER key 2 seconds to select the CALIBRATE menu 5 seconds to select the OPTIONS menu Step 2 The Key Code is UP UP UP DOWN keys in sequence After entering the Key Cod...

Page 8: ...L Single point calibration for Level Reset LVL to Factory Cal Yes Reset Level to original factory calibration Set LVL entry is erased No Return to menu do not reset Level Loop Source LVL Select the so...

Page 9: ...for relay response Relay will be activated only if the source value exceeds the setpoint for this time period Relay settings will repeat for Relay 2 and for External Relays External Relays require th...

Page 10: ...t Test Relay 1 Press UP or DOWN keys to manually toggle the state of Relay 1 Display Factory settings shown Description VOL Shape Vert Cylinder Select the shape of the vessel where Sensor is located V...

Page 11: ...iew all custom points and reset values so each point is greater than the preceding point CHK SENSOR Problem with the sensor during different modes of operation 1 Wiring problem AUXILIARY POWER was not...

Page 12: ...upply Note When using the 8059 4 or 8059 4AC only relays 1 and 2 can be utilized with the flow instrument Accessories Mfr Part No Code Description 3 8050 159 000 184 Universal mounting kit 3 8050 395...

Reviews: