H. CONTINUOUS MODE
Note: Disregard the following if your machine was supplied with the optional
single cycle / continuous switch.
The machine has been sent to you equipped with a foot pedal. Once the
foot pedal is depressed, the machine will complete one cycle and then shut off,
until the foot pedal is depressed again. If you wish to have the machine cycle
continuously, you can perform the following procedure. First disconnect the air
supply. There are two lines of air tubing coming from the filler to the foot pedal.
About 6 to 12 inches from the foot pedal there are two plastic instant tube fittings.
By pulling back on the end of either one of the plastic connectors in one hand,
and with the tubing in the other hand, the tubing will be released (see illustration
below). (You are in the process of disconnecting the foot pedal from the
machine). On the second tube, remove the tubing with the fitting still attached.
At this point you should have one tube with a fitting and the second one is just
the tube by itself. Connect the open tube into the open end of the fitting on the
other tube (closing the loop). When the air is reconnected the machine will cycle
continuously.
I. ADJUSTMENT FOR QUANTITY OF FILL
The volume of product that this filling machine dispenses depends upon
the size of the inside diameter of the fill cylinder that is supplied with this
machine. (Other sizes can be obtained from our facility, just call 800-453-6213)
And the length of the stroke that the piston takes. The stroke of the piston is
adjustable, thereby allowing the machine to deliver different volumes.