JOINON WALLBOX I-CON BASIC recharging unit for electric vehicles
2.1
FULFILMENT OF REGULATIONS
CE marking
CE marking is essential for marketing the products in question within the European Union and the European Eco-
nomic Area. The charging stations have CE marking as they comply with the following directives:
• Low Voltage Directive 2014/35/EU
• Electromagnetic Compatibility directive 2014/30/EU
• RED directive 2014/53/EU (version with RFID and/or GSM)
Low Voltage directive
The recharging stations comply with this directive as they fulfil the applicable parts of the harmonised standard
EN
61851-1 Electric vehicle conductive charging system - Part 1: General requirements
Electromagnetic Compatibility directive
The charging stations comply with this directive, as they fulfil the applicable parts of the harmonised standards:
•
IEC 61851-21-2 Electric vehicle conductive charging system - Part 21-2: Electric vehicle requirements for
conductive connection to an AC/DC supply - EMC requirements for off board electric vehicle charging systems
•
EN 61000-6-1 Electromagnetic compatibility. Part 6-1: Generic standards - Immunity for residential, commer-
cial and light-industrial environments
•
EN 61000-6-3 Electromagnetic compatibility. Part 6-3: Generic standards - Emissions for residential, commer-
cial and light-industrial environments
RED directive
The charging stations comply with this directive, as they fulfil the applicable parts of the harmonised standards:
•
ETSI EN 300 330V 2.1.1
•
ETSI EN 301 511 V 12.1.10 (GSM)
Fulfilment with this standard requires compliance with the requirements and procedures of the other standards
in the same series.
2.2.
DEGREE OF PROTECTION
These charging stations have an IP55 degree of protection against external agents.
This device is designed for indoor and outdoor use.
2.3.
POLLUTION RATING
The pollution degree that these stations are designed for is level 3 with reference to Standard IEC 60664-1.
2.4.
CURRENT SOCKET-OUTLETS
The charging stations can be supplied with various connector configurations, depending on the customer's require-
ments.
The following connectors are available:
REGULATORY ASPECTS
2.
IEC 62196-2 Type 2 - cable + mobile connector
IEC 62196-2 Type 2 - flush-mounting version