Operation of a smoke detector is limited in the following
areas:
• in bathrooms, garages or kitchens.
• in drafty areas, e.g. near ventilator shafts.
• in extremely dusty areas.
• in areas with high ambient humidity.
Minimum
protection
Maximum
protection
Mounting and installation
• Choose a suitable area to mount the detector, on the
ceiling in the centre of the room according to
Fig. 5
to
Fig. 7
.
• Follow the installation instructions according to
Fig. 7
.
No objects or obstacles should be found within a
50 cm radius around the smoke detector.
• Attach the mounting plate to the ceiling according to
Fig. 3
.
• Insert the battery and connect it correctly according
to
Fig. 2
. The red LED fl ashes approx. every 45
seconds
Fig. 3C
.
• Place the smoke detector onto the installed mounting
plate and carefully turn it in a clockwise direction until it
clicks into place
Fig. 3A + 3B
.
• Check that each installed smoke detector is operating
correctly using the test key
Fig. 3C
.
Comprehensive alarm system and connecting
several smoke detectors together
To immediately and clearly hear the warning signal of
each individual smoke detector, we recommend that you
connect the individual smoke detectors together.
Up to 30 smoke detectors can be connected together by
wire or radio.
• Use J-Y(St)Y2x2x0.6 or AWG 23 wires and connect
them according to
Fig. 4
. Make sure the cables are
connected correctly: plus to plus and minus to minus.
• Connect individual smoke detectors according to
Fig. 4
.
• When all smoke detectors have been connected
together, perform a function test.
• Press and hold the test key
Fig. 3C
on a connected
smoke detector for approx. 20 seconds to trigger the
alarm on all the smoke detectors.
Function
The smoke detector automatically performs a self-test
every 45 seconds. The LED fl ashes briefl y to indicate this.
• Test the device each time you replace the battery.
• Check that the smoke detector is operating correctly at
least once a year using the test key
Fig. 3C
.
Battery and rechargeable battery information
Old batteries may not be disposed of with the
unsorted household waste. Owners of used
batteries are legally obliged to recycle the batteries
and can return them free of charge to the place of
sale. Batteries contain material which is harmful to the
environment and health, and must therefore be disposed
of professionally.
Recycling instructions
This device must not be disposed of with unsorted
household waste. Owners of old devices are
required by law to dispose of this device correctly.
Contact your town council for further information.
Correct action in the event of a fi re
Keep calm!
Alert the fi re service.
It is important that the fi re service is told the following
information:
• Your name (name, phone number)
• The location of the fi re (address)
• What has happened (extent of fi re)
• How many people are injured
• Then wait to see if the operator has any questions.
Alert all the people who live with you.
Help aged, sick and disabled persons.
Close all windows and doors.
Do not use lifts.
If you have any doubts as to whether or not it is a genuine
alarm, still act as if there is a real fi re.
Tone
Red LED
Description
Intermittent alarm signal
Flashes at the same time as the
audible alarm signal
Alarm triggered on individual detector if
smoke is detected. Automatically resets
if no smoke is detected
Intermittent alarm signal
No LED
Alarm triggered by connected detector.
The triggered detector can be identifi ed
by an intermittent alarm signal and
fl ashing LED. Automatically resets if no
smoke is detected
Short signal emitted approx.
every 45 seconds
Flashes at the same time as the
audible signal
Replace the battery
No signal
Flashes every 45 seconds
Device is ready for use
Short signal emitted approx.
every 45 seconds
Flashes alternately with the
audible signal
Faulty, replace the device
Technical information
Product
Smoke alarm FMR 3033, FMR 3392, type 32
Smoke alarm FMR 3569, type 34
Alarm display
visual (red LED) and acoustic
Operating voltage
FMR 3033, FMR 3392, 9 V , alkaline battery included
FMR 3569, 9 V , lithium battery included
Recommended batteries Ultralife U9VL lithium battery, Energizer 6LR61, Duracell MN1604, Power Line 6LR61
Temperature range
0 °C...+55 °C
Signal volume
85 dB/3 m
CPD number
0786-CPD-20564
VdS number
G200057
Standard
DIN EN 14604:2009-02
CE marking
2011
Measurements
Ø 110 mm x H 40 mm
Gutkes GmbH
Rehkamp 13